Industrial Automation Parts. Prompt replies from real people.

Schneider TMC2TI2 Analogue Input Cartridge

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the Schneider TMC2TI2?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider TMC2TI2 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
TMC2TI2
Material Number
—
Manufacturer
Schneider
Product ID
34718

Get a Free Quote

Request pricing and availability for TMC2TI2.

More parts to source? Send your whole list in one enquiry

Key specifications

Product or component type
Analogue input cartridge
Range of product
Modicon M221
Product compatibility
Modicon M221C
Analogue input number
2
Analogue input type
thermocouple - 200...1000 °C with thermocouple J / thermocouple - 200...1300 °C with thermocouple K / thermocouple 0...1760 °C with thermocouple R / thermocouple 0...1760 °C with thermocouple S / thermocouple 0...1820 °C with thermocouple B / thermocouple - 200...400 °C with thermocouple T / thermocouple - 200...1300 °C with thermocouple N / thermocouple - 200...800 °C with thermocouple E / thermocouple 0...2315 °C with thermocouple C / Ni 100/Ni 1000 temperature probe - 60...180 °C / Pt 100 temperature probe - 200...850 °C / Pt 1000 temperature probe - 200...600 °C
Analogue input resolution
14 bits
See all specifications

Product Highlights

  1. Product Type: Analogue input cartridge for Modicon M221 systems, compatible with Modicon M221C controllers
  2. Input Count: 2 analogue inputs
  3. Thermocouple Inputs: J -200...1000 °C, K -200...1300 °C, R 0...1760 °C, S 0...1760 °C, B 0...1820 °C, T -200...400 °C, N -200...1300 °C, E -200...800 °C, CNi 0...2315 °C
  4. Temperature Probe Inputs: Ni 100/Ni 1000 -60...180 °C, Pt 100 -200...850 °C, Pt 1000 -200...600 °C
  5. Resolution and Sampling: 14-bit analogue input resolution, 0.1 °C LSB, 125 ms sampling for thermocouple and 250 ms for temperature probe
  6. Accuracy: +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000 and Ni 100/Ni 1000 probes, +/- 0.4 % of full scale at 25 °C for thermocouple K -200...0 °C, +/- 0.1 % of full scale for other ranges
  7. Electrical Connection: 3 x 1.5 mm² 2 screw terminal blocks, 3.81 mm pitch, for inputs
  8. Cable and Insulation: Twisted shielded pairs cable up to 30 m, non-insulated between analogue input and internal logic
  9. Input Impedance and Immunity: >= 1 MOhm input impedance, 10 ms immunity to microbreaks
TMC2TI2

Product Information

Technical Specifications

Specifications for TMC2TI2
ParameterValue
Product or component typeAnalogue input cartridge
Range of productModicon M221
Product compatibilityModicon M221C
Analogue input number2
Analogue input typethermocouple - 200...1000 °C with thermocouple Jthermocouple - 200...1300 °C with thermocouple Kthermocouple 0...1760 °C with thermocouple Rthermocouple 0...1760 °C with thermocouple Sthermocouple 0...1820 °C with thermocouple Bthermocouple - 200...400 °C with thermocouple Tthermocouple - 200...1300 °C with thermocouple Nthermocouple - 200...800 °C with thermocouple Ethermocouple 0...2315 °C with thermocouple CNi 100/Ni 1000 temperature probe - 60...180 °CPt 100 temperature probe - 200...850 °CPt 1000 temperature probe - 200...600 °C
Analogue input resolution14 bits
LSB value0.1 °C
Sampling duration125 ms, analogue input type: thermocouple / 250 ms, analogue input type: temperature probe
Absolute accuracy error+/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe+/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C+/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C+/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C+/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C+/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C+/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C+/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C+/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C+/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C+/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C+/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C+/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C
Repeat accuracy+/- 0.5 %FS
Electrical connection3 x 1.5 mm² 2 screw terminal blocks with pitch 3.81 mm adjustment for inputs
Height41 mm
Width35 mm
Depth15 mm
Temperature drift+/- 0.02 %FS/°C

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp