Q1Can you supply the Schneider RMPT23BD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider RMPT23BD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
RMPT23BD
Material Number
—
Manufacturer
Schneider
Product ID
33764

Get a Free Quote

Request pricing and availability for RMPT23BD.

More parts to source? Send your whole list in one enquiry

Key specifications

abnormal analogue output current
-30…0 mA when no input or input wire broken / 22…30 mA when no input or input wire broken
abnormal analogue output voltage
-15...-11 V when no input or input wire broken / 11...15 V when no input or input wire broken
Net weight
0.12 kg
IP degree of protection
IP20 (terminal block) / IP50 (housing)
See all specifications

Product Highlights

  1. Probe Compatibility: Converter for Pt100 temperature probes with 2, 3, or 4 wires
  2. Input Range: -100...100 °C (-148...212 °F)
  3. Output Type: Voltage 0...10 V with load >= 100 kOhm
  4. Supply Voltage: 24 V DC non-isolated, +/- 20 %
  5. Current Consumption: <= 40 mA for voltage output and <= 60 mA for current output
  6. Protection: Reverse polarity protection on power supply, overvoltage protection on output (+/- 30 V), reverse polarity protection on output, and short-circuit protection on output
  7. Abnormal Output: -15...-11 V or 11...15 V and -30...0 mA or 22...30 mA with no input or broken input wire
  8. Measurement Error: +/- 0.5 % of full scale for 3 or 4 wires at 20 °C, +/- 1 % of full scale for 2 wires at 20 °C, with temporary performance degradation under electromagnetic interference
  9. Repeat Accuracy: +/- 0.2 % of full scale at 20 °C and +/- 0.6 % of full scale at 60 °C
  10. Temperature Coefficient: 150 ppm/°C
  11. Maximum Wiring Resistance: 0.2 Ohm for 2 wires
  12. Local Signalling: LED (green) for power ON
  13. Mounting: Clip-on for 35 mm symmetrical DIN rail or fixed mounting plate
  14. Dimensions: 31 mm x 80 mm x 78 mm
  15. Weight: 0.12 kg
RMPT23BD

Product Information

Technical Specifications

Specifications for RMPT23BD

ParameterValue
Product or component typeConverter for Optimum Pt100 probes
Range of productHarmony Analog
abnormal analogue output current-30…0 mA when no input or input wire broken / 22…30 mA when no input or input wire broken
Current consumption<= 40 mA for voltage output / <= 60 mA for current output
MarkingCE
Analogue input typeRTD - 100...100 °C/- 148...212 °F Pt 100 2, 3 or 4 wires
Analogue output typeCurrent 4...20 mA / Voltage 0...10 V
abnormal analogue output voltage-15...-11 V when no input or input wire broken / 11...15 V when no input or input wire broken
ParameterValue
Local signallingLED (green) for power ON
Clamping connection capacity2 x 1.5 mm² / 1 x 2.5 mm²
Net weight0.12 kg
IP degree of protectionIP20 (terminal block) / IP50 (housing)
Ambient air temperature for operation0…50 °C mounting side by side / 0…60 °C 2 cm spacing
Protection typeReverse polarity protection on power supplyOvervoltage protection on output (+/- 30 V)Reverse polarity protection on outputShort-circuit protection on output
Product certificationsCSAULGL

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.