Industrial Automation Parts. Prompt replies from real people.

Schneider LC1F500N722L TeSys F Nonreversing Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the Schneider LC1F500N722L?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1F500N722L cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1F500N722L
Material Number
—
Manufacturer
Schneider
Product ID
33491

Get a Free Quote

Request pricing and availability for LC1F500N722L.

More parts to source? Send your whole list in one enquiry

Key specifications

Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage
415 V AC 40...400 Hz
[Ie] rated operational current
700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
Hold-in power consumption in VA
18 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
IP degree of protection
IP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
See all specifications

Product Highlights

  1. -
LC1F500N722L

Product Information

Technical Specifications

Specifications for LC1F500N722L

ParameterValue
Range of ProductTeSys F
Product or Component TypeContactor
Device short nameLC1F
Contactor applicationMotor controlResistive load
Utilisation categoryAC-4AC-3AC-1
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz <= 460 V DC
[Uc] control circuit voltage415 V AC 40...400 Hz
[Ie] rated operational current700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current700 A (at 104 °F (40 °C))
Rated breaking capacity4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current4200 A 104 °F (40 °C) - 10 s3200 A 104 °F (40 °C) - 30 s2400 A 104 °F (40 °C) - 1 min1500 A 104 °F (40 °C) - 3 min1200 A 104 °F (40 °C) - 10 min
Associated fuse rating500 A aM at <= 440 V800 A gG at <= 440 V
Average impedance0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Power dissipation per pole88 W AC-145 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Auxiliary contact composition2 NO + 2 NC
Motor power kW250 kW at 380...400 V AC 50/60 Hz (AC-3)280 kW at 415 V AC 50/60 Hz (AC-3)295 kW at 440 V AC 50/60 Hz (AC-3)355 kW at 500 V AC 50/60 Hz (AC-3)335 kW at 660...690 V AC 50/60 Hz (AC-3)335 kW at 1000 V AC 50/60 Hz (AC-3)147 kW at 220...230 V AC 50/60 Hz (AC-3)80 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA)150 hp at 200 V AC200 hp at 230 V AC400 hp at 460 V AC500 hp at 575 V AC
Control circuit voltage limitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
ParameterValue
Mechanical durability10 Mcycles
Inrush power in VA1100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate2400 cyc/h 131 °F (55 °C)
Operating time40...65 ms closing100...170 ms opening
Connections - terminalsControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable endPower circuit bolted connectionPower circuit 2 bars 40 x 5 mmPower circuit lugs-ring terminals 2 0.4 in² (240 mm²)
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m)Power circuit 309.8 lbf.in (35 N.m)
Mounting SupportPlate
Heat dissipation18 W
StandardsIEC 60947-4-1EN 60947-4-1JIS C8201-4-1EN 60947-1IEC 60947-1
Product CertificationsULCCCDNVLROS (Lloyds register of shipping)BVABSRMRoSRINACB
Hold-in power consumption in VA18 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
IP degree of protectionIP20 front face with shrouds IEC 60529IP20 front face with shrouds VDE 0106
Protective treatmentTH
Ambient Air Temperature for Operation23...131 °F (-5...55 °C)
Ambient Air Temperature for Storage-76...176 °F (-60...80 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C)
Mechanical robustnessVibrations contactor open2 Gn, 5...300 HzShocks contactor open9 Gn for 11 msShocks contactor closed15 Gn for 11 msVibrations contactor closed4 Gn, 5...300 Hz
Height15.7 in (400 mm)
Width9.2 in (233 mm)
Depth9.1 in (232 mm)
Operating altitude9842.52 ft (3000 m) without derating

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp