Industrial Automation Parts. Prompt replies from real people.

Schneider LC1F4004F7 TeSys F Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the Schneider LC1F4004F7?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1F4004F7 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1F4004F7
Material Number
—
Manufacturer
Schneider
Product ID
33435

Get a Free Quote

Request pricing and availability for LC1F4004F7.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz / <= 460 V DC
[Ie] rated operational current
500 A (at <40 °C) at <= 440 V AC AC-1
[Uc] control circuit voltage
110 V AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529 / IP20 front face with shrouds conforming to VDE 0106
See all specifications

Product Highlights

  1. High Current Rating: 500 A rated operational current at 40 °C and up to 440 V AC in AC-1, with 500 A conventional free air thermal current at 40 °C
  2. Voltage Range: Up to 1000 V AC at 50/60 Hz and up to 460 V DC operational voltage, with 110 V AC control circuit voltage at 40 to 400 Hz
  3. Short-Time Withstand Current: 3600 A for 10 s, 2400 A for 30 s, 1700 A for 1 min, 1200 A for 3 min, and 1000 A for 10 min at 40 °C
  4. Breaking Capacity and Fuse Coordination: 3200 A rated breaking capacity per IEC 60947-4-1, with 400 A aM or 500 A gG associated fuse at up to 440 V
  5. Insulation and Impulse Withstand: 1000 V rated insulation voltage per IEC 60947-4-1 and 1500 V per VDE 0110 group C, with 8 kV rated impulse withstand voltage
  6. Power Dissipation and Impedance: 65 W per pole in AC-1 and 0.26 mOhm average impedance at Ith 500 A and 50 Hz
  7. Mechanical Durability and Operating Rate: 10 million mechanical cycles and maximum operating rate of 2400 cycles per hour at 55 °C
  8. Operating Time: 40 to 65 ms closing and 100 to 170 ms opening
  9. Contact Configuration: 4 NO power poles for resistive load AC-1 applications
  10. Terminal Connections: Control circuit screw clamp terminals for 1 to 4 mm² flexible or solid conductors, power circuit bar 30 x 5 mm, lugs-ring terminals 150 mm², or bolted connection
  11. Tightening Torque: 1.2 N.m for control circuit and 35 N.m for power circuit
  12. Mounting and Protection: Plate mounting with IP20 front face protection and TH protective treatment
  13. Ambient Temperature Range: -5 to 55 °C operating, -60 to 80 °C storage, and -40 to 70 °C permissible around the device
  14. Operating Altitude: Up to 3000 m without derating
  15. Standards and Certifications: IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, JIS C8201-4-1, with RINA, RMRoS, CB, CCC, DNV, ABS, LROS, BV, UL, and UKCA certifications
  16. Dimensions and Weight: 206 mm height, 261 mm width, 219 mm depth, and 10.2 kg net weight
LC1F4004F7

Product Information

Technical Specifications

Specifications for LC1F4004F7

ParameterValue
Product or component typeContactor
Range of productTeSys F
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz / <= 460 V DC
[Ie] rated operational current500 A (at <40 °C) at <= 440 V AC AC-1
[Uc] control circuit voltage110 V AC 40...400 Hz
Control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) / Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)
Power dissipation per pole65 W AC-1
RangeTeSys
Connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mmPower circuit: lugs-ring terminals 2 cable(s) 150 mm²Power circuit: bolted connection
ParameterValue
Height206 mm
Width261 mm
Depth219 mm
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 / IP20 front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-5…55 °C
Product certificationsRINARMRoSCBCCCDNVABSLROS (Lloyds register of shipping)BVULUKCA

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.