Product Model
LC1F400P7
Material Number
—
Manufacturer
Schneider
Product ID
33257

Get a Free Quote

Request pricing and availability for LC1F400P7.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz / <= 460 V DC
[Ie] rated operational current
500 A (at <40 °C) at <= 440 V AC AC-1 / 400 A (at <55 °C) at <= 440 V AC AC-3
[Uc] control circuit voltage
230 V AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529 / IP20 front face with shrouds conforming to VDE 0106
See all specifications

Product Highlights

  1. Contactor Application: Motor control and resistive load
  2. Utilisation Category: AC-1, AC-3, AC-4
  3. Poles Description: 3P, 3 NO power pole contact composition
  4. Rated Operational Voltage: <= 1000 V AC 50/60 Hz, <= 460 V DC
  5. Control Circuit Voltage: 230 V AC, 40...400 Hz
  6. Rated Operational Current: 500 A at <= 440 V AC AC-1 (at 40 °C), 400 A at <= 440 V AC AC-3 (at 55 °C)
  7. Motor Power: 200 kW at 380...400 V AC, 220 kW at 415 V AC, 250 kW at 440 V AC, 257 kW at 500 V AC, 280 kW at 660...690 V AC, 185 kW at 1000 V AC (AC-3), 75 kW at 400 V AC (AC-4)
  8. Rated Impulse Withstand Voltage: 8 kV
  9. Conventional Free Air Thermal Current: 500 A at 40 °C
  10. Rated Breaking Capacity: 3200 A conforming to IEC 60947-4-1
  11. Rated Short-time Withstand Current: 3600 A at 40 °C for 10 s, 2400 A at 40 °C for 30 s, 1700 A at 40 °C for 1 min, 1200 A at 40 °C for 3 min, 1000 A at 40 °C for 10 min
  12. Associated Fuse Rating: 400 A aM at <= 440 V, 500 A gG at <= 440 V
  13. Rated Insulation Voltage: 1000 V IEC 60947-4-1, 1500 V VDE 0110 group C
  14. Average Impedance: 0.26 mOhm at Ith 500 A 50 Hz
  15. Power Dissipation per Pole: 65 W AC-1, 42 W AC-3
  16. Overvoltage Category: III
  17. Mechanical Durability: 10 Mcycles
  18. Maximum Operating Rate: 2400 cyc/h at 55 °C
  19. Operating Time: 40...65 ms closing, 100...170 ms opening
  20. Connections: Control circuit screw clamp terminals 1...4 mm² flexible/solid, power circuit bar 30 x 5 mm, lugs-ring terminals 150 mm², bolted connection
  21. Tightening Torque: Control circuit 1.2 N.m, power circuit 35 N.m
  22. Mounting Support: Plate
  23. Heat Dissipation: 14 W
  24. Motor Starter Type: Direct on-line contactor
  25. Standards: EN 60947-1, EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1
  26. Product Certifications: ABS, CSA, UL, BV, DNV, RMR, RoSL, LROS (Lloyds register of shipping), CB, RINA, UKCA
  27. IP Degree of Protection: IP20 front face with shrouds IEC 60529, IP20 front face with shrouds VDE 0106
  28. Protective Treatment: TH
  29. Ambient Air Temperature for Operation: -5...55 °C
  30. Ambient Air Temperature for Storage: -60...80 °C
  31. Permissible Ambient Air Temperature Around the Device: -40...70 °C
  32. Dimensions: 206 mm height, 213 mm width, 219 mm depth
  33. Operating Altitude: 3000 m without derating
  34. Net Weight: 9.1 kg
LC1F400P7

Product Information

Technical Specifications

Specifications for LC1F400P7

ParameterValue
Product or component typeContactor
Range of productTeSys F
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz / <= 460 V DC
[Ie] rated operational current500 A (at <40 °C) at <= 440 V AC AC-1 / 400 A (at <55 °C) at <= 440 V AC AC-3
[Uc] control circuit voltage230 V AC 40...400 Hz
Control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) / Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)
Power dissipation per pole65 W AC-1 / 42 W AC-3
RangeTeSys
Connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mmPower circuit: lugs-ring terminals 2 cable(s) 150 mm²Power circuit: bolted connection
ParameterValue
Height206 mm
Width213 mm
Depth219 mm
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 / IP20 front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-5…55 °C
Product certificationsABSCSAULBVDNVRMRoSLROS (Lloyds register of shipping)CBRINAUKCA

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.