Industrial Automation Parts. Prompt replies from real people.

Schneider LC1D95Q7 TeSys D Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the Schneider LC1D95Q7?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1D95Q7 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1D95Q7
Material Number
—
Manufacturer
Schneider
Product ID
32849

Get a Free Quote

Request pricing and availability for LC1D95Q7.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
[Ie] rated operational current
95 A (at <60 °C) at <= 440 V AC-3 for power circuit / 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit / 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage
380 V AC 50/60 Hz
IP degree of protection
IP20 front face conforming to IEC 60529
See all specifications

Product Highlights

  1. Product Type: Schneider Electric TeSys Deca LC1D contactor with 3 NO power poles
  2. Applications: Resistive load and motor control in AC-1, AC-3, AC-3e, and AC-4 utilisation categories
  3. Rated Operational Current: 95 A at up to 440 V AC-3 and AC-3e, 125 A at up to 1000 V AC-1, all at up to 60 °C
  4. Motor Power: 25 kW at 220...230 V AC-3, 45 kW at 380...400 V and 415...440 V AC-3, 55 kW at 500 V AC-3, 45 kW at 660...690 V AC-3, 15 kW at 400 V AC-4
  5. Maximum Horse Power Rating: 7.5 hp at 120 V AC single phase, 15 hp at 230/240 V AC single phase, 30 hp at 200/208 V and 230/240 V AC three phase, 60 hp at 460/480 V and 575/600 V AC three phase
  6. Control Circuit: 380 V AC 50/60 Hz coil without built-in suppressor module, operational from 0.8...1.1 Uc at -40...55 °C
  7. Auxiliary Contacts: 1 NO + 1 NC mechanically linked and mirror contact
  8. Mounting: DIN-rail or plate mounting with screw clamp control terminals and connector power terminals
  9. Standards and Certifications: IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, UL 60947-4-1, CSA C22.2 No 14, CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
LC1D95Q7

Product Information

Technical Specifications

Specifications for LC1D95Q7
ParameterValue
Product or component typeContactor
Range of productTeSys Deca Advanced
[Ue] rated operational voltagePower circuit: <= 1000 V AC 25...400 Hz
[Ie] rated operational current95 A (at <60 °C) at <= 440 V AC-3 for power circuit125 A (at <60 °C) at <= 1000 V AC-1 for power circuit95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage380 V AC 50/60 Hz
Control circuit voltage limits0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz1...1.1 Uc (55…70 °C):operational AC 50/60 Hz
Motor power kW25 kW at 220/230 V AC 50/60 Hz (AC-3)45 kW at 380/400 V AC 50/60 Hz (AC-3)45 kW at 415/440 V AC 50/60 Hz (AC-3)55 kW at 500 V AC 50/60 Hz (AC-3)45 kW at 660/690 V AC 50/60 Hz (AC-3)45 kW at 1000 V AC 50/60 Hz (AC-3)25 kW at 220/230 V AC 50/60 Hz (AC-3e)45 kW at 380/400 V AC 50/60 Hz (AC-3e)45 kW at 415/440 V AC 50/60 Hz (AC-3e)55 kW at 500 V AC 50/60 Hz (AC-3e)45 kW at 660/690 V AC 50/60 Hz (AC-3e)45 kW at 1000 V AC 50/60 Hz (AC-3e)15 kW at 400 V AC 50/60 Hz (AC-4)
RangeTeSys
Connections - terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: connector 1 4…50 mm² - cable stiffness: flexible without cable endPower circuit: connector 2 4…25 mm² - cable stiffness: flexible without cable endPower circuit: connector 1 4…50 mm² - cable stiffness: flexible with cable endPower circuit: connector 2 4…16 mm² - cable stiffness: flexible with cable endPower circuit: connector 1 4…50 mm² - cable stiffness: solid without cable endPower circuit: connector 2 4…25 mm² - cable stiffness: solid without cable end
Height127 mm
Width85 mm
Depth130 mm
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C / 60…70 °C with derating
Product certificationsCCCULCB SchemeCSACEUKCAMarineEAC

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.