Industrial Automation Parts. Prompt replies from real people.

Schneider LC1D40AL7 TeSys D Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the Schneider LC1D40AL7?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1D40AL7 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1D40AL7
Material Number
—
Manufacturer
Schneider
Product ID
31913

Get a Free Quote

Request pricing and availability for LC1D40AL7.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC
[Ie] rated operational current
60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
200 V AC 50/60 Hz
Maximum Horse Power Rating
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 3 phase motors30 hp at 575/600 V AC 50/60 Hz for 3 phase motors10 hp at 200/208 V AC 50/60 Hz for 3 phase motors3 hp at 115 V AC 50/60 Hz for 1 phase motors30 hp at 460/480 V AC 50/60 Hz for 3 phase motors
Signalling circuit frequency
25...400 Hz
Net Weight
1.87 lb(US) (0.85 kg)
See all specifications

Product Highlights

  1. -
LC1D40AL7

Product Information

Technical Specifications

Specifications for LC1D40AL7

ParameterValue
RangeTeSysTeSys Deca
Range of ProductTeSys Deca
Product or Component TypeContactor
Device short nameLC1D
Contactor applicationResistive loadMotor control
Utilisation categoryAC-4AC-1AC-3AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC
[Ie] rated operational current60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage200 V AC 50/60 Hz
Motor power kW18.5 kW at 380...400 V AC 50/60 Hz (AC-3)11 kW at 220...230 V AC 50/60 Hz (AC-3)22 kW at 415...440 V AC 50/60 Hz (AC-3)22 kW at 500 V AC 50/60 Hz (AC-3)30 kW at 660...690 V AC 50/60 Hz (AC-3)9 kW at 400 V AC 50/60 Hz (AC-4)18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)11 kW at 220...230 V AC 50/60 Hz (AC-3e)22 kW at 415...440 V AC 50/60 Hz (AC-3e)22 kW at 500 V AC 50/60 Hz (AC-3e)30 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating5 hp at 230/240 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 3 phase motors30 hp at 575/600 V AC 50/60 Hz for 3 phase motors10 hp at 200/208 V AC 50/60 Hz for 3 phase motors3 hp at 115 V AC 50/60 Hz for 1 phase motors30 hp at 460/480 V AC 50/60 Hz for 3 phase motors
compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 140 °F (60 °C)) for signalling circuit60 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 104 °F (40 °C) - 10 s for power circuit720 A 104 °F (40 °C) - 1 s for power circuit72 A 104 °F (40 °C) - 10 min for power circuit165 A 104 °F (40 °C) - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole2.4 W AC-35.4 W AC-12.4 W AC-3e
[Ui] rated insulation voltagePower circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULPower circuit 690 V IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 60 A AC-1 <= 440 V1.5 Mcycles 40 A AC-3 <= 440 V1.5 Mcycles 40 A AC-3e <= 440 V
Control circuit typeAC 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc -40...158 °F (-40...70 °C) drop-out AC 50/60 Hz0.8...1.1 Uc -40...140 °F (-40...60 °C) operational AC 50 Hz0.85...1.1 Uc -40...140 °F (-40...60 °C) operational AC 60 Hz1...1.1 Uc 140...158 °F (60...70 °C) operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
ParameterValue
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation4...5 W at 50/60 Hz
Operating time4...19 ms opening12...26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections - terminalsControl circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable endPower circuit: EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: solid without cable endPower circuit: EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: solid without cable end
Tightening torqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04...0.05 in² (25...35 mm²) hexagonal 0.2 in (4 mm)Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002...0.04 in² (1...25 mm²) hexagonal 0.2 in (4 mm)Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeMechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
Mounting SupportPlateRail
StandardsEN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1CSA C22.2 No 14UL 60947-4-1IEC 60335-2-40:Annex JJUL 60335-2-40:Annex JJIEC 60335-1:Clause 30.2
Product CertificationsCCCULCB SchemeCSACEUKCAMarineEAC
IP degree of protectionIP20 front face IEC 60529
Protective treatmentTHIEC 60068-2-30
Climatic withstandIACS E10 exposure to damp heat IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C)140...158 °F (60...70 °C) with derating
Operating altitude0...9842.52 ft (0...3000 m)
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor closed 15 Gn for 11 ms) Shocks contactor open 10 Gn for 11 ms)
Height4.8 in (122 mm)
Width2.2 in (55 mm)
Depth4.7 in (120 mm)
Net Weight1.87 lb(US) (0.85 kg)

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp