| Range of Product | TeSys Deca |
|---|
| Product or Component Type | Contactor |
|---|
| Device short name | LC1D |
|---|
| Contactor application | Motor controlResistive load |
|---|
| Utilisation category | AC-4AC-1AC-3AC-3e |
|---|
| Poles description | 3P |
|---|
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC |
|---|
| [Ie] rated operational current | 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit40 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit25 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
|---|
| [Uc] control circuit voltage | 200 V AC 50/60 Hz |
|---|
| Motor power kW | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3)11 kW at 380...400 V AC 50/60 Hz (AC-3)11 kW at 415...440 V AC 50/60 Hz (AC-3)15 kW at 500 V AC 50/60 Hz (AC-3)15 kW at 660...690 V AC 50/60 Hz (AC-3)5.5 kW at 400 V AC 50/60 Hz (AC-4)5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)11 kW at 380...400 V AC 50/60 Hz (AC-3e)11 kW at 415...440 V AC 50/60 Hz (AC-3e)15 kW at 500 V AC 50/60 Hz (AC-3e)15 kW at 660...690 V AC 50/60 Hz (AC-3e) |
|---|
| Maximum Horse Power Rating | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors15 hp at 460/480 V AC 50/60 Hz for 3 phase motors20 hp at 575/600 V AC 50/60 Hz for 3 phase motors7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors |
|---|
| compatibility code | LC1D |
|---|
| Pole contact composition | 3 NO |
|---|
| Protective cover | With |
|---|
| [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit40 A (at 140 °F (60 °C)) for power circuit |
|---|
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1450 A at 440 V for power circuit conforming to IEC 60947 |
|---|
| Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 |
|---|
| [Icw] rated short-time withstand current | 240 A 104 °F (40 °C) - 10 s for power circuit380 A 104 °F (40 °C) - 1 s for power circuit50 A 104 °F (40 °C) - 10 min for power circuit120 A 104 °F (40 °C) - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
|---|
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit40 A gG at <= 690 V coordination type 2 for power circuit |
|---|
| Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
|---|
| Power dissipation per pole | 3.2 W AC-11.25 W AC-31.25 W AC-3e |
|---|
| [Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V UL |
|---|
| Overvoltage category | III |
|---|
| Pollution degree | 3 |
|---|
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
|---|
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
|---|
| Mechanical durability | 15 Mcycles |
|---|
| Electrical durability | 1.65 Mcycles 25 A AC-3 <= 440 V1.4 Mcycles 40 A AC-1 <= 440 V1.65 Mcycles 25 A AC-3e <= 440 V |
|---|
| Control circuit type | AC 50/60 Hz |
|---|
| Coil technology | Without built-in suppressor module |
|---|
| Control circuit voltage limits | 0.3...0.6 Uc -40...158 °F (-40...70 °C) drop-out AC 50/60 Hz0.8...1.1 Uc -40...140 °F (-40...60 °C) operational AC 50 Hz0.85...1.1 Uc -40...140 °F (-40...60 °C) operational AC 60 Hz1...1.1 Uc 140...158 °F (60...70 °C) operational AC 50/60 Hz |
|---|
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
|---|