Q1Can you supply the Schneider LC1D18ED?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1D18ED cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1D18ED
Material Number
—
Manufacturer
Schneider
Product ID
31513

Get a Free Quote

Request pricing and availability for LC1D18ED.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit / 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit / 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
48 V DC
IP degree of protection
IP20 front face conforming to IEC 60529
See all specifications

Product Highlights

  1. 3-pole contactor with 3 NO power poles and 1 NO + 1 NC auxiliary contacts: rated operational current 18 A at up to 440 V AC in AC-3 and AC-3e, 32 A in AC-1, with a power circuit rated voltage up to 690 V AC or 300 V DC
  2. Motor power ratings in AC-3 and AC-3e: 4 kW at 220...230 V, 7.5 kW at 380...400 V, 9 kW at 415...440 V, 10 kW at 500 V and 10 kW at 660...690 V, all at 50/60 Hz
  3. Maximum horsepower ratings: 1 hp at 115 V and 3 hp at 230/240 V for single-phase motors, 5 hp at 200/208 V and 230/240 V, 10 hp at 460/480 V and 15 hp at 575/600 V for three-phase motors
  4. 48 V DC control circuit with integral suppression device: operating range 0.7...1.25 Uc from -40 to 60 °C, closing time 63 ms and opening time 20 ms
  5. Screw clamp terminals for control and power circuits: power circuit accepts 1.5...6 mm² flexible or solid cable, control circuit accepts 1...4 mm², tightening torque 1.7 N·m
  6. Mounting on plate or rail: 45 mm width, 77 mm height, 95 mm depth, IP20 front face, ambient temperature -40...60 °C with derating up to 70 °C
LC1D18ED

Product Information

Technical Specifications

Specifications for LC1D18ED
ParameterValue
Product or component typeContactor
Range of productTeSys Deca Advanced
[Ue] rated operational voltagePower circuit: <= 690 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage48 V DC
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC0.7...1.25 Uc (-40…60 °C):operational DC1...1.25 Uc (60…70 °C):operational DC
Motor power kW4 kW at 220/230 V AC 50/60 Hz (AC-3)7.5 kW at 380/400 V AC 50/60 Hz (AC-3)9 kW at 415/440 V AC 50/60 Hz (AC-3)10 kW at 500 V AC 50/60 Hz (AC-3)10 kW at 660/690 V AC 50/60 Hz (AC-3)4 kW at 220/230 V AC 50/60 Hz (AC-3e)7.5 kW at 380/400 V AC 50/60 Hz (AC-3e)9 kW at 415/440 V AC 50/60 Hz (AC-3e)10 kW at 500 V AC 50/60 Hz (AC-3e)10 kW at 660/690 V AC 50/60 Hz (AC-3e)4 kW at 400 V AC 50/60 Hz (AC-4)
Device short nameLC1D
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end
Height77 mm
Width45 mm
Depth95 mm
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C / 60…70 °C with derating
Product certificationsULCCCCSAMarineUKCAEACCB Scheme

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.