Industrial Automation Parts. Prompt replies from real people.

Schneider LC1D09JD IEC Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the Schneider LC1D09JD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Schneider LC1D09JD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
LC1D09JD
Material Number
—
Manufacturer
Schneider
Product ID
31409

Get a Free Quote

Request pricing and availability for LC1D09JD.

More parts to source? Send your whole list in one enquiry

Key specifications

[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit / 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit / 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
12 V DC
IP degree of protection
IP20 front face conforming to IEC 60529
See all specifications

Product Highlights

  1. Product Range: TeSys Deca contactor, device short name LC1D
  2. Contactor Application: Resistive load and motor control
  3. Utilisation Category: AC-3, AC-1, AC-4, AC-3e
  4. Poles Description: 3P with 3 NO pole contact composition
  5. Rated Operational Voltage: Power circuit up to 690 V AC at 25 to 400 Hz, and up to 300 V DC
  6. Rated Operational Current: 9 A at up to 440 V AC for AC-3 and AC-3e, and 25 A at up to 440 V AC for AC-1, at up to 60 °C
  7. Control Circuit Voltage: 12 V DC
  8. Motor Power: 2.2 kW at 220 to 230 V AC, 4 kW at 380 to 400 V AC, 4 kW at 415 to 440 V AC, 5.5 kW at 500 V AC, and 5.5 kW at 660 to 690 V AC, at 50/60 Hz for AC-3 and AC-3e
  9. Motor Power: 2.2 kW at 400 V AC at 50/60 Hz for AC-4
  10. Maximum Horse Power Rating: 0.33 hp at 115 V AC, 1 hp at 230/240 V AC for 1 phase motors, 2 hp at 200/208 V AC, 2 hp at 230/240 V AC, 5 hp at 460/480 V AC, and 7.5 hp at 575/600 V AC for 3 phase motors
  11. Auxiliary Contact Composition: 1 NO + 1 NC, mechanically linked and mirror contact
  12. Connections - Terminals: Screw clamp terminals for power and control circuits, accepting 1 to 4 mm² flexible or solid cable
  13. Tightening Torque: 1.7 N.m for power and control circuit screw clamp terminals
  14. Mounting Support: Rail or plate
  15. Standards: IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 14, CSA C22.2 No 60947-4-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, UL 60335-2-40 Annex JJ
  16. Product Certifications: UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
  17. IP Degree of Protection: IP20 front face IEC 60529
  18. Permissible Ambient Air Temperature Around the Device: -40 to 60 °C, with derating up to 70 °C
  19. Operating Altitude: 0 to 3000 m
  20. Mechanical Durability: 30 Mcycles
  21. Electrical Durability: 0.6 Mcycles at 25 A AC-1 up to 440 V, 2 Mcycles at 9 A AC-3 up to 440 V, 2 Mcycles at 9 A AC-3e up to 440 V
  22. Safety Reliability Level: B10d = 1369863 cycles with nominal load, B10d = 20000000 cycles with mechanical load, EN/ISO 13849-1
  23. Coil Technology: Built-in bidirectional peak limiting diode suppressor
  24. Control Circuit Voltage Limits: 0.1 to 0.25 Uc drop-out at -40 to 70 °C, 0.7 to 1.25 Uc operational at -40 to 60 °C, 1 to 1.25 Uc operational at 60 to 70 °C
  25. Operating Time: 63 ±15% ms closing, 20 ±20% ms opening
  26. Maximum Operating Rate: 3600 cyc/h at 60 °C
  27. Dimensions: 77 mm height, 45 mm width, 95 mm depth
  28. Net Weight: 0.48 kg
LC1D09JD

Product Information

Technical Specifications

Specifications for LC1D09JD
ParameterValue
Product or component typeContactor
Range of productTeSys Deca Advanced
[Ue] rated operational voltagePower circuit: <= 690 V AC 25...400 Hz / Power circuit: <= 300 V DC
[Ie] rated operational current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage12 V DC
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC0.7...1.25 Uc (-40…60 °C):operational DC1...1.25 Uc (60…70 °C):operational DC
Motor power kW2.2 kW at 220/230 V AC 50/60 Hz (AC-3)4 kW at 380/400 V AC 50/60 Hz (AC-3)4 kW at 415/440 V AC 50/60 Hz (AC-3)5.5 kW at 500 V AC 50/60 Hz (AC-3)5.5 kW at 660/690 V AC 50/60 Hz (AC-3)2.2 kW at 220/230 V AC 50/60 Hz (AC-3e)4 kW at 380/400 V AC 50/60 Hz (AC-3e)4 kW at 415/440 V AC 50/60 Hz (AC-3e)5.5 kW at 500 V AC 50/60 Hz (AC-3e)5.5 kW at 660/690 V AC 50/60 Hz (AC-3e)2.2 kW at 400 V AC 50/60 Hz (AC-4)
Device short nameLC1D
Connections - terminalsPower circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Height77 mm
Width45 mm
Depth95 mm
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C / 60…70 °C with derating
Product certificationsULCCCCSAMarineUKCAEACCB Scheme

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp