| type of electrical connection | spring-loaded terminal (push-in) |
|---|
| type of connectable conductor cross-sections / solid | 1x (0,75 ... 1,5), 2x (0,75 ... 1,0), 2x 1,5 |
|---|
| type of connectable conductor cross-sections / finely stranded with core end processing | 1x (0,75 ... 1,5), 2x 0,75 |
|---|
| type of connectable conductor cross-sections / finely stranded without core end processing | 1x (0,75 ... 1,5), 2x (0,75 ... 1,0), 2x 1,5 |
|---|
| type of connectable conductor cross-sections / for AWG cables solid | 1x (18 ... 16), 2x (18 ... 16) |
|---|
| type of connectable conductor cross-sections / for AWG cables stranded | 1x (18 ... 16), 2x (18 ... 16) |
|---|
| connectable conductor cross-section / solid | 0.75 ... 1.5 mm² |
|---|
| connectable conductor cross-section / finely stranded with core end processing | 0.75 ... 1.5 mm² |
|---|
| connectable conductor cross-section / finely stranded without core end processing | 0.75 ... 1.5 mm² |
|---|
| AWG number as coded connectable conductor cross section / solid | 18 ... 16 |
|---|
| AWG number as coded connectable conductor cross section / stranded | 18 ... 16 |
|---|
| mounting position | any |
|---|
| fastening method | snap-on mounting |
|---|
| height | 98 mm |
|---|
| width | 15.5 mm |
|---|
| depth | 71 mm |
|---|
| required spacing / with side-by-side mounting / — forwards | 0 mm |
|---|
| required spacing / with side-by-side mounting / — backwards | 0 mm |
|---|
| required spacing / with side-by-side mounting / — upwards | 0 mm |
|---|
| required spacing / with side-by-side mounting / — downwards | 0 mm |
|---|
| required spacing / with side-by-side mounting / — at the side | 0 mm |
|---|
| required spacing / for grounded parts / — forwards | 0 mm |
|---|
| required spacing / for grounded parts / — backwards | 0 mm |
|---|
| required spacing / for grounded parts / — upwards | 0 mm |
|---|
| required spacing / for grounded parts / — at the side | 0 mm |
|---|
| required spacing / for grounded parts / — downwards | 0 mm |
|---|
| required spacing / for live parts / — forwards | 0 mm |
|---|
| required spacing / for live parts / — backwards | 0 mm |
|---|
| required spacing / for live parts / — upwards | 0 mm |
|---|
| required spacing / for live parts / — downwards | 0 mm |
|---|
| required spacing / for live parts / — at the side | 0 mm |
|---|
| ambient temperature / during operation | -40 ... +70 °C |
|---|
| ambient temperature / during storage | -20 ... +70 °C |
|---|
| ambient temperature / during transport | -20 ... +70 °C |
|---|