Product identification: Phoenix Contact MINI MCR-SL-PT100-UI-200-NC. The MINI MCR-SL-PT100-UI-200-NC is a signal conditioner for Pt 100 temperature sensors. It supports 2-, 3-, and 4-wire connections according to IEC 60751. The measuring range is -150°C to +850°C. Configuration is performed via DIP switches. An error is indicated by a diagnostic LED and by the analog output signal. The compact housing allows integration into confined installation spaces.
The MINI MCR-SL-PT100-UI-NC is a signal conditioner from Phoenix Contact for connecting Pt 100 resistance thermometers. It provides 3-way electrical isolation. The module is configured via DIP switches. Analog signal outputs include 0...20 mA and 4...20 mA. Its width is 6.2 mm.
The Phoenix Contact MINI MCR-SL-R-UI is a signal conditioner that converts potentiometer positions to an analog standard signal. The output signal range is configurable using DIP switches. The module has a width of 6.2 mm. It carries approval for Ex-zone 2 (nA) for use in potentially explosive areas. Configuration is performed via accessible DIP switches.
The MINI MCR-SL-RPS-I-I is a signal conditioner and measuring transducer from Phoenix Contact for standard applications. It provides electrical isolation to maintain signal integrity in field circuits and can operate as either an isolator or a repeater power supply. The module accepts a supply voltage of 19.2 V DC to 30 V DC. Its compact housing measures 6.2 mm in width and 93.1 mm in height. The unit is classified under EMC class A.
The Phoenix Contact MINI MCR-SL-RPSS-I-I is a compact signal conditioner and measuring transducer for standard applications. It supports bidirectional HART transmission. Maximum transmission error is less than 0.2 %. Its compact design allows installation in tight spaces.
The MINI MCR-SL-SHUNT-UI-NC is a configurable 3-way isolating amplifier from Phoenix Contact for converting DC current signals measured across shunt resistors. Input and output signal ranges are set with DIP switches. The module provides electrical isolation between input, output, and supply to prevent signal interference. It has a width of 6.2 mm and is designed for DIN rail mounting.
The MINI MCR-SL-U-I-0 is a signal conditioner and measuring transducer from Phoenix Contact for standard analog signal applications. It provides electrical isolation for signal processing and can be configured via DIP switches for signal range settings. The module accepts standard analog signals including 0...20 mA, 4...20 mA, and 0...10 V. Its 6.2 mm width supports DIN rail mounting. Transmission error is less than 0.1% with alignment.
The MINI MCR-SL-U-I-4 is a signal conditioner and measuring transducer from Phoenix Contact for standard applications. It provides 3-way isolation for electrical separation between input, output, and supply. Input and output signal ranges are configurable. The module uses screw connections. Its compact housing supports integration into control cabinets and other equipment where space is limited. Power consumption is low.
WhatsAppMINI MCR-SL-PT100-LP-NC Temperature Transducer by Phoenix Contact