- IB IL SSI-IN-PAC
The Phoenix Contact IB IL SSI-IN-PAC is an SSI input module for remote I/O systems. It provides measurement resolution up to 25 bits and supplies 5 V to the encoder. The module operates with 24 V I/O voltage. It is intended for absolute rotation or position measurement systems. The connection is shielded to reduce noise. Use this module where an SSI encoder interface is required within a compatible remote I/O station.
- IB IL SSI-PAC
The Phoenix Contact IB IL SSI-PAC is an SSI interface module with integrated monitoring functions. It provides an adjustable encoder offset and a software limit switch. The module is intended for use within the Inline modular I/O system.
- IB IL SSI/INC-PLSET
Phoenix Contact IB IL SSI/INC-PLSET is an interface module for SSI and incremental encoder signals. The module provides flexible conductor cross sections for connection to device manufacturers' control systems. It is supplied as part of a product portfolio that includes technical data for product selection. The module is intended for use in industrial automation environments where SSI or incremental encoder signals are processed.
- IB IL TEMP 2 RTD
The Phoenix Contact IB IL TEMP 2 RTD is a temperature measurement module for RTD sensors. It provides 16-bit resolution and supports Pt, Ni, KTY, and Cu sensor types. Sensor connection is selectable in 2-, 3-, and 4-wire technology. The module has a compact housing for DIN rail mounting.
- IB IL TEMP 2 RTD-PAC
The Phoenix Contact IB IL TEMP 2 RTD-PAC is a remote I/O module for resistance temperature detector inputs. It supports platinum, nickel, copper, and KTY sensors in accordance with DIN EN 60751 and SAMA. Measurement resolution is 16 bits. Channels can be parameterized independently through the bus system. The module is specified for ambient conditions from -40 °C to +70 °C. An inline connector and a labeling field are included.
- IB IL TEMP 2 RTD-PAC/10
The Phoenix Contact IB IL TEMP 2 RTD-PAC/10 is a temperature measurement module for RTD sensors. It supports platinum and nickel sensors according to DIN EN 60751 and SAMA. Temperature measurement resolution is 16 bits. The two channels can be parameterized independently of each other via the bus system. The module operates over an extended ambient temperature range of -40 °C to +70 °C. An Inline connector and a labeling field are included for installation.
- IB IL TEMP 2 RTD-XC-PAC
The Phoenix Contact IB IL TEMP 2 RTD-XC-PAC is a remote I/O module in the Inline series for temperature measurement with resistance temperature detectors. It provides two RTD input channels and is part of the XC (extreme conditions) variant. The module is supplied as a PAC (package) unit. It is intended for use within an Inline remote I/O station, where it occupies a terminal position and communicates with the station's bus coupler or controller. The RTD inputs accept resistance temperature detector signals for temperature acquisition in industrial automation systems. Installation and wiring follow the Inline system's terminal and connector conventions. For channel-specific measurement ranges, sensor types, accuracy, and environmental ratings, refer to the module's technical data.
- IB IL TEMP 2 UTH
The Phoenix Contact IB IL TEMP 2 UTH is a temperature input module for thermocouple signals. It supports thermocouple types U, T, L, J, E, K, N, S, R, B, C, W, and HK. Measurement resolution is 16-bit. The module accepts a linear voltage input range of -15 mV to +85 mV. Sensor characteristic curves are configurable through process data. Its dimensions are 12.2 mm wide, 136.8 mm high, and 71.5 mm deep.