Q1Can you supply the SIEMENS 6GK1411-6CA40-0BA0?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 6GK1411-6CA40-0BA0 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
6GK1411-6CA40-0BA0
Material Number
6gk14116ca400ba0
Manufacturer
SIEMENS
Product ID
1248618

Get a Free Quote

Request pricing and availability for 6GK1411-6CA40-0BA0.

More parts to source? Send your whole list in one enquiry

Key specifications

product type designation
IE/WSN-PA LINK - - spare part - - IE/WSN-PA LINK for external antenna port; gateway between WirelessHART and Ethernet; Ethernet 10/100 Mbps; TCP/IP, Modbus TCP; WirelessHART at 2.4 GHz; national approval Europe; EX-perm. Zone 2; RS 485 with Modbus RTU.
type of voltage supply
DC
supply voltage / external
24 V
protection class IP
IP65
net weight
4.54 kg
operating frequency / for WirelessHART in 2.4 GHz frequency
2.4 ... 2.5 GHz
See all specifications
6GK1411-6CA40-0BA0

Product Information

Technical Specifications

Specifications for 6GK1411-6CA40-0BA0

ParameterValue
product type designationIE/WSN-PA LINK - - spare part - - IE/WSN-PA LINK for external antenna port; gateway between WirelessHART and Ethernet; Ethernet 10/100 Mbps; TCP/IP, Modbus TCP; WirelessHART at 2.4 GHz; national approval Europe; EX-perm. Zone 2; RS 485 with Modbus RTU.
at the 1st interface10 ... 100 Mbit/s
at the 2nd interface10 ... 100 Mbit/s
at the 3rd interface9.6 ... 57.6 kbit/s
at the 1st interface / according to Industrial Ethernet1
at the 2nd interface / according to Industrial Ethernet1
at the 3rd interface / according to RS 4851
for power supply1
at the 1st interface / according to Industrial EthernetRJ45 port
at the 2nd interface / according to Industrial EthernetRJ45 port
at the 3rd interface / according to RS 4852-pole terminal strip
for power supply3-pole terminal strip
number of radio cards / permanently installed1
number of internal antennas0
number of electrical connections / for external antenna(s)1
type of electrical connection / for external antenna(s)N-Connector
type of voltage supplyDC
supply voltage / external24 V
supply voltage / external20 ... 28 V
type of voltage / of the supply voltageDC
consumed current / from external supply voltage / at DC / at 240.5 A
power loss [W] / maximum12 W
during operation-40 ... +70 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
relative humidity / at 25 °C / without condensation / during90 %
protection class IPIP65
width / of the enclosure229 mm
without antenna306 mm
with antenna354 mm
depth / of the enclosure89 mm
net weight4.54 kg
fastening methodMaterial for mast mounting included in scope of delivery
wall mountingYes
mast mountingYes
operating frequency / for WirelessHART in 2.4 GHz frequency2.4 ... 2.5 GHz
number of WirelessHART devices / operable100
at 100 field devices / for WirelessHART network /10 s
for 50 field devices / for WirelessHART network /5 s
transmission link / between two devices / for WirelessHART100 m
noteValues may vary in the case of radio obstacles
protocol / is supported / HART protocolYes
Address Resolution Protocol (ARP)Yes
HTTPYes
HTTPSYes
Modbus TCPYes
Modbus TCP secureYes
Modbus RTUYes
web-based managementYes
DHCP clientYes
web-based diagnosticsYes
WirelessHART diagnostics via ModbusYes
product function / device redundancyYes
password protection - multi-levelYes
WirelessHART Join KeyYes
ParameterValue
ACL - MAC-basedYes
WirelessHART Network IDYes
protocol / is supported / SSLYes
principle of encryptionAES 128 bit
protocol / is supported / NTPYes
standard / for WirelessHARTHART V 7.1
standard for wireless communication / IEEE 802.15.4Yes
CE markingYes
relating to CSACSA Division 2 & Dust Ignition-proof for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, Groups E, F, and GSuitable for Class III Hazardous Locations.Install per Siemens drawing A5E02467236A. Temperature Code: T4 (-40°C < Ta < 60°C) CSA Enclosure Type 4X
relating to FMFM Division 2, Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, III, Division 1, Groups E, F, and GIndoor and outdoor locationsNEMA Type 4X Temperature Code: T4 (-40°C < Ta < 60°C)
relating to ATEXATEX type n, see note: Certificate number: Baseefa10ATEX0044X, ATEX marking: Ex II 3 G, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof: Certificate number: Baseefa10ATEX0045X, ATEX marking: II 3 D, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted.
relating to IECExIECEx Type n, see note: Certificate number: IECEx BAS 10.0014X, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX dust ignition-proof, see note: Certificate number: IECEx BAS 10.0015X, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation. The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when the device is mounted.
wireless approvalIC approval
to web page: selection aid TIA Selection Toolhttps://www.siemens.com/tstcloud
to website: Industrial communicationhttps://www.siemens.com/simatic-net
to website: Industry Mallhttps://mall.industry.siemens.com
to website: Information and Download Centerhttp://www.siemens.com/industry/infocenter
to website: Image databasehttps://www.automation.siemens.com/bilddb
to website: CAx-Download-Managerhttps://www.siemens.com/cax
to website: Industry Online Supporthttps://support.industry.siemens.com
security informationSiemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
last modified:3/10/2026

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp