- DS202 M AC-C50/0.03
ABB DS202 M AC-C50/0.03 is an industrial catalog item. Key specifications include Standards: IEC/EN 60947-2 IEC/EN 61009-1, Tripping Characteristic: C, Type of Residual Current: Type AC, and Rated Voltage (U r ): 230 V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202 M AC-C6/0.03
ABB DS202 M AC-C6/0.03 is an industrial catalog item. Key specifications include Standards: IEC/EN 60947-2 IEC/EN 61009-1, Tripping Characteristic: C, Type of Residual Current: Type AC, and Rated Voltage (U r ): 230 V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202 M AC-C63/0.03
ABB DS202 M AC-C63/0.03 is an industrial catalog item. Key specifications include Standards: IEC/EN 60947-2 IEC/EN 61009-1, Tripping Characteristic: C, Type of Residual Current: Type AC, and Rated Voltage (U r ): 230 V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202CR B20 A30
ABB DS202CR B20 A30 is an industrial catalog item. Key specifications include Standards: IEC/EN 61009-1 IEC/EN 61009-2-1, Tripping Characteristic: B, Type of Residual Current: Type A, and Rated Operational Voltage: acc. to IEC 60898-1 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202CR B32 A30
ABB DS202CR B32 A30 is an industrial catalog item. Key specifications include Standards: IEC/EN 61009-1 IEC/EN 61009-2-1, Tripping Characteristic: B, Type of Residual Current: Type A, and Rated Operational Voltage: acc. to IEC 60898-1 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202CR B32 A300
ABB DS202CR B32 A300 is an industrial catalog item. Key specifications include Standards: IEC/EN 61009-1 IEC/EN 61009-2-1, Tripping Characteristic: B, Type of Residual Current: Type A, and Rated Operational Voltage: acc. to IEC 60898-1 230 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- DS202CR B40 A30
ABB DS202CR B40 A30 is a two-pole residual current circuit breaker with overcurrent protection. It has a rated current of 40 A, a rated residual current of 30 mA, Type A residual current, and B tripping characteristic. Rated operational voltage is 230 V AC according to IEC 60898-1, with rated insulation voltage 440 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated frequency is 50 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 6 kA. Maximum surge current is 0.25 kA. Power loss is 8.92 W. Electrical endurance is 10000 operations and mechanical endurance is 20000 operations. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Manufacturer ID: 2CSR752140R1405.
- DS202CR B40 A300
ABB DS202CR B40 A300 is a two-pole residual current circuit breaker with overcurrent protection, identified by manufacturer ID 2CSR752140R3405. It has a B tripping characteristic and Type A residual current detection. Rated current is 40 A, rated residual current is 300 mA, and rated operational voltage is 230 V AC according to IEC 60898-1. Rated frequency is 50 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 6 kA. Maximum surge current is 0.25 kA. Rated insulation voltage is 440 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Power loss is 8.92 W. Electrical endurance is 10000 operations and mechanical endurance is 20000 operations. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.