Industrial Automation Parts. Prompt replies from real people.

SIEMENS 7PV15081AW30

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the SIEMENS 7PV15081AW30?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 7PV15081AW30 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
7PV15081AW30
Material Number
7pv15081aw30
Manufacturer
SIEMENS
Product ID
123556

Get a Free Quote

Request pricing and availability for 7PV15081AW30.

More parts to source? Send your whole list in one enquiry

Key specifications

insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value
300 V
Net Weight
73.58 g
type of voltage of the control supply voltage
AC/DC
control supply voltage frequency 1
50 ... 60 Hz
design of the fuse link for short-circuit protection of the auxiliary switch required
fuse gL/gG: 4 A
operational current of auxiliary contacts at AC-15 / maximum
3 A
See all specifications
7PV15081AW30

Product Information

Technical Specifications

Specifications for 7PV15081AW30

ParameterValue
product brand nameSIRIUS
product designationtiming relay
design of the productMultifunctional
product type designation7PV15
product component semi-conductor outputNo
product extension required remote controlNo
product extension optional remote controlNo
power loss [W] maximum2 W
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
test voltage for isolation test2.2 kV
degree of pollution2
surge voltage resistance rated value4 000 V
test voltage for surge voltage test4 800 V
shock resistance according to IEC 60068-2-2711 g / 15 ms
vibration resistance according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
mechanical service life (operating cycles) typical10 000 000
electrical endurance (operating cycles) at AC-15 at 230 V typical100 000
adjustable time0.05 s ... 100 h
relative setting accuracy relating to full-scale value5 %; +/-
ON period/maximum minimum35 ms
recovery time500 ms
reference code according to IEC 81346-2K
relative repeat accuracy2 %; +/-
influence of the surrounding temperature2% in complete temperature range for the set duration
power supply influence2% in complete voltage range for the set duration
Substance Prohibitance (day/month/year)05/01/2012
Net Weight73.58 g
type of voltage of the control supply voltageAC/DC
control supply voltage at AC / at 50 Hz rated value12 ... 240 V
control supply voltage at AC / at 60 Hz rated value12 ... 240 V
control supply voltage 1 at AC / at 50 Hz12 ... 240 V
control supply voltage 1 at AC / at 60 Hz12 ... 240 V
control supply voltage frequency 150 ... 60 Hz
control supply voltage at DC rated value12 ... 240 V
control supply voltage 1 at DC12 ... 240 V
operating range factor control supply voltage rated value at DC / initial value0.85
operating range factor control supply voltage rated value at DC / full-scale value1.1
operating range factor control supply voltage rated value at AC at 50 Hz / initial value0.85
operating range factor control supply voltage rated value at AC at 50 Hz / full-scale value1.1
operating range factor control supply voltage rated value at AC at 60 Hz / initial value0.85
operating range factor control supply voltage rated value at AC at 60 Hz / full-scale value1.1
switching function / ON-delayYes
switching function / ON-delay/instantaneous contactNo
switching function / passing make contactYes
switching function / passing make contact/instantaneous contactNo
switching function / OFF delayNo
switching function / flashing symmetrically with interval start/instantaneousNo
switching function / flashing symmetrically with interval startYes
switching function / flashing symmetrically with pulse start/instantaneousNo
switching function / flashing symmetrically with pulse startNo
switching function / flashing asymmetrically with interval startNo
switching function / flashing asymmetrically with pulse startNo
switching function / star-delta circuit with delay timeNo
switching function / star-delta circuitNo
switching function with control signal / additive ON-delayYes
switching function with control signal / passing break contactYes
switching function with control signal / passing break contact/instantaneousNo
switching function with control signal / OFF delayYes
switching function with control signal / OFF delay/instantaneousNo
switching function with control signal / pulse delayedNo
switching function with control signal / pulse delayed/instantaneousNo
switching function with control signal / pulse-shapingYes
switching function with control signal / pulse-shaping/instantaneousNo
switching function with control signal / additive ON-delay/instantaneousNo
switching function with control signal / ON-delay/OFF-delayNo
switching function with control signal / ON-delay/OFF-delay/instantaneousNo
switching function with control signal / passing make contactNo
switching function with control signal / passing make contact/instantaneous contactNo
switching function of interval relay with control signal / retrotriggerable with deactivated control signal/instantaneous contactNo
switching function of interval relay with control signal / retrotriggerable with switched-on control signalNo
switching function of interval relay with control signal / retrotriggerable with switched-on control signal/instantaneous contactNo
switching function of interval relay with control signal / retriggerable with deactivated control signalNo
design of the control terminal non-floatingYes
design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 4 A
material of switching contactsAgSnO2
number of NC contacts / delayed switching0
number of NC contacts / instantaneous contact0
ParameterValue
number of NO contacts / delayed switching0
number of NO contacts / instantaneous contact0
number of CO contacts / delayed switching1
number of CO contacts / instantaneous contact0
operational current of auxiliary contacts at AC-15 / maximum3 A
operational current of auxiliary contacts at AC-15 / at 24 V3 A
operational current of auxiliary contacts at AC-15 / at 250 V3 A
operational current of auxiliary contacts as NC contact at AC-15 / at 24 V3 A
operational current of auxiliary contacts as NC contact at AC-15 / at 250 V3 A
operational current of auxiliary contacts as NO contact at AC-15 / at 24 V3 A
operational current of auxiliary contacts as NO contact at AC-15 / at 250 V3 A
operational current of auxiliary contacts at DC-131 ... 0.01
operational current of auxiliary contacts at DC-13 / at 24 V1 A
operational current of auxiliary contacts at DC-13 / at 125 V0.22 A
operational current of auxiliary contacts at DC-13 / at 250 V0.1 A
operating frequency with 3RT2 contactor maximum5 000 1/h
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
contact rating of auxiliary contacts according to ULR150 / B300
switching capacity current with inductive load0.01 ... 3 A
product function / at the relay outputs switchover delayed/without delayNo
product function / non-volatileNo
ampacity of the output relay at AC-15 at 250 V at 50/60 Hz3 A
ampacity of the output relay at DC-13 / at 24 V1 A
ampacity of the output relay at DC-13 / at 125 V0.22 A
EMC immunity according to IEC 61812-1EN 61000-6-2
conducted interference / due to burst according to IEC 61000-4-42 kV network connection / 1 kV control connection
conducted interference / due to conductor-earth surge according to IEC 61000-4-52 kV
conducted interference / due to conductor-conductor surge according to IEC 61000-4-51 kV
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
category according to EN 954-1none
protection class IP on the front according to IEC 60529IP20
type of insulationBasic insulation
product component removable terminal for auxiliary and control circuitNo
type of electrical connectionscrew terminal
type of electrical connection / for auxiliary and control circuitscrew-type terminals
type of connectable conductor cross-sections / solid1x (0.2 ... 2.5 mm²)
type of connectable conductor cross-sections / finely stranded with core end processing1x (0.25 ... 1.5 mm²)
type of connectable conductor cross-sections / finely stranded without core end processing1x (0.2 ... 1.5 mm²)
type of connectable conductor cross-sections / for AWG cables solid1x (24 ... 14)
type of connectable conductor cross-sections / for AWG cables stranded1x (24 ... 14)
connectable conductor cross-section / solid0.2 ... 2.5 m²
connectable conductor cross-section / finely stranded with core end processing0.25 ... 1.5 m²
connectable conductor cross-section / finely stranded without core end processing0.2 ... 1.5 m²
AWG number as coded connectable conductor cross section / solid24 ... 14
AWG number as coded connectable conductor cross section / stranded24 ... 14
mounting positionany
fastening methodsnap-on fastening on 35 mm DIN rail
height90 mm
width17.5 mm
depth66.7 mm
required spacing / with side-by-side mounting / — forwards0 mm
required spacing / with side-by-side mounting / — backwards0 mm
required spacing / with side-by-side mounting / — upwards0 mm
required spacing / with side-by-side mounting / — downwards0 mm
required spacing / with side-by-side mounting / — at the side0 mm
required spacing / for grounded parts / — forwards0 mm
required spacing / for grounded parts / — backwards0 mm
required spacing / for grounded parts / — upwards0 mm
required spacing / for grounded parts / — at the side0 mm
required spacing / for grounded parts / — downwards0 mm
required spacing / for live parts / — forwards0 mm
required spacing / for live parts / — backwards0 mm
required spacing / for live parts / — upwards0 mm
required spacing / for live parts / — downwards0 mm
required spacing / for live parts / — at the side0 mm
installation altitude at height above sea level maximum2 000 m
ambient temperature / during operation-25 ... +55 °C
ambient temperature / during storage-40 ... +70 °C
ambient temperature / during transport-40 ... +70 °C
relative humidity during operation15 ... 85 %
global warming potential [CO2 eq] / during manufacturing1.34 kg
global warming potential [CO2 eq] / during operation21.2 kg
global warming potential [CO2 eq] / after end of life-0.156 kg
global warming potential [CO2 eq] / total22.4 kg

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
7PV15081AW30 | SIEMENS | INDPRT