- dpa-40-10
FESTO air booster DPA-40-10, manufacturer ID 537273. Twin-piston pressure intensifier with 40 mm piston diameter. Inlet pressure 1: 2.5 bar to 8 bar (0.25 MPa to 0.8 MPa; 36.25 psi to 116 psi). Outlet pressure 2 and pressure regulation range: 4.5 bar to 10 bar (0.45 MPa to 1 MPa; 65.25 psi to 145 psi). If the controller spring is tensioned to the maximum, the maximum output pressure may be exceeded by 40%. Operating medium: compressed air as per ISO 8573-1:2010 [7:3:4]; operation with oil lubrication not possible. Pneumatic connections 1 and 2: G1/4; connection 3: M7. Pressure gauge connection G1/8 prepared. Mounting position any; mounting with internal thread. Ambient and storage temperature 5°C to 60°C. Weight 1500 g. Corrosion resistance class 2. LABS conformity VDMA24364-B1/B2-L. RoHS-compliant.
- dpa-40-10-crvzs2
The FESTO DPA-40-10-CRVZS2 (Manufacturer ID 552928) is a twin-piston pressure intensifier with an integrated air reservoir, pressure gauge, and non-return valve. It has a 40 mm piston diameter and 2 l reservoir volume. Inlet pressure 1 is 2 bar to 8 bar (0.2 MPa to 0.8 MPa; 29 psi to 116 psi); outlet pressure 2 is 4.5 bar to 10 bar (0.45 MPa to 1 MPa; 65.25 psi to 145 psi). Operating pressure is 36.25 psi to 116 psi. The operating medium is compressed air as per ISO 8573-1:2010 [7:3:4]; oil lubrication is not possible. Ambient and storage temperature range is 5°C to 60°C. The air reservoir is high-alloy stainless steel. Pneumatic connections are QS-10, KD4, and a pneumatic muffler. Mounting is any position with slot nuts. Weight is 4400 g. Corrosion resistance class 2.
- dpa-40-16
Festo DPA-40-16 air booster, manufacturer ID 537274. Twin-piston pressure intensifier with 40 mm piston diameter, mountable in any position via internal thread. Pneumatic connections 1 and 2 are G1/4; connection 3 is M7. Inlet pressure 1 is 2.5 bar to 10 bar (0.25 MPa to 1 MPa; 36.25 psi to 145 psi). Outlet pressure 2 and pressure regulation range are 4.5 bar to 16 bar (0.45 MPa to 1.6 MPa; 65.25 psi to 232 psi). If the controller spring is tensioned to the maximum, maximum output pressure may be exceeded by 40%. Operating medium is compressed air per ISO 8573-1:2010 [7:3:4]; oil lubrication is not possible. Ambient and storage temperature range is 5°C to 60°C. Weight 1500 g. Pressure gauge connection G1/8 prepared. CRC 2; LABS conformity VDMA24364-B1/B2-L; RoHS-compliant.
- dpa-40-16-crvzs2
The Festo DPA-40-16-CRVZS2 is a twin-piston pressure intensifier with an integrated 2 l air reservoir, pressure gauge, and non-return valve. It has a 40 mm piston diameter and can be mounted in any position using slot nuts. Inlet pressure 1 is 2 bar to 8 bar (0.2 MPa to 0.8 MPa; 29 psi to 116 psi), and outlet pressure 2 is 4.5 bar to 16 bar (0.45 MPa to 1.6 MPa; 65.25 psi to 232 psi). Operating medium is compressed air as per ISO 8573-1:2010 [7:3:4]; operation with oil lubrication is not possible. Ambient and storage temperatures are 5°C to 60°C. Pneumatic connections are QS-10, KD4, and a pneumatic muffler. Weight is 4400 g. The air reservoir is high-alloy stainless steel; the product is RoHS-compliant.
- dpa-40-16-crvzs5
Festo air booster DPA-40-16-CRVZS5, manufacturer ID 552931. Twin-piston pressure intensifier with air reservoir, pressure gauge, and non-return valve. Piston diameter 40 mm; reservoir volume 5 l in high-alloy stainless steel. Inlet pressure 1: 2 bar to 8 bar (0.2 MPa to 0.8 MPa; 29 psi to 116 psi). Outlet pressure 2 and pressure regulation range: 4.5 bar to 16 bar (0.45 MPa to 1.6 MPa; 65.25 psi to 232 psi). Operating pressure 36.25 psi to 116 psi. Operating medium: compressed air as per ISO 8573-1:2010 [7:3:4]; oil lubrication not possible. Mounting position: condensate drain downwards; mounting with slot nuts. Pneumatic connections: QS-10, KD4, and pneumatic muffler. Ambient and storage temperature 5°C to 60°C. Max. tightening torque for condensate drain 27 Nm. Weight 7300 g. Corrosion resistance class 2. LABS conformity VDMA24364-B1/B2-L. RoHS-compliant. CE marking as per EU pressure equipment directive; UKCA marking according to UK regulations for pressure equipment.
- dpa-40-d
Festo DPA-40-D air booster, manufacturer ID 549396, is a twin-piston pressure intensifier with a 40 mm piston diameter. It can be mounted in any position and uses internal-thread mounting. Pneumatic connections 1 and 2 are G1/4; connection 3 is M7. Inlet pressure 1 is 2.5 bar to 8 bar (0.25 MPa to 0.8 MPa; 36.25 psi to 116 psi). Outlet pressure 2 is 5 bar to 16 bar (72.5 psi to 232 psi). The pressure regulation range is 4 bar to 16 bar (0.4 MPa to 1.6 MPa; 58 psi to 232 psi). Operating medium is compressed air per ISO 8573-1:2010 [7:3:4]; oil-lubricated operation is not possible. A G1/8 pressure gauge connection is prepared. Ambient and storage temperature range is 5°C to 60°C. Weight is 1500 g. Corrosion resistance class 2; LABS conformity VDMA24364-B1/B2-L; RoHS-compliant.
- dpa-63-10
Festo DPA-63-10 twin-piston pressure intensifier with 63 mm piston diameter. Mounting position is any; mounting is via internal thread. Pneumatic connections 1, 2, and 3 are G3/8. Inlet pressure 1 is 2 bar to 8 bar (0.2 MPa to 0.8 MPa; 29 psi to 116 psi). Outlet pressure 2 and pressure regulation range are 4 bar to 10 bar (0.4 MPa to 1 MPa; 58 psi to 145 psi). If the controller spring is tensioned to the maximum, the maximum output pressure may be exceeded by 40%. Operating medium is compressed air as per ISO 8573-1:2010 [7:3:4]; operation with oil lubrication is not possible. Ambient and storage temperature range is 5°C to 60°C. Product weight is 6000 g. Pressure gauge connection is G1/8 prepared. Corrosion resistance class 2. LABS conformity per VDMA24364-B1/B2-L. RoHS-compliant.
- dpa-63-10-a
The Festo DPA-63-10-A (manufacturer ID 549399) is a twin-piston pressure intensifier with a 63 mm piston diameter and piston magnet. It can be mounted in any position using internal threads. Pneumatic connections 1, 2, and 3 are G3/8; a G1/8 pressure gauge connection is prepared. Inlet pressure 1 is 2 bar to 8 bar (0.2 MPa to 0.8 MPa; 29 psi to 116 psi). Outlet pressure 2 and the pressure regulation range are 4 bar to 10 bar (0.4 MPa to 1 MPa; 58 psi to 145 psi). If the controller spring is tensioned to the maximum, the maximum output pressure may be exceeded by 40%. Operating medium is compressed air as per ISO 8573-1:2010 [7:3:4]; operation with oil lubrication is not possible. Ambient and storage temperature range is 5°C to 60°C. Weight is 6000 g. Corrosion resistance class is 2 (moderate corrosion stress), and the product is RoHS-compliant.