- OVR 110E
ABB OVR 110E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 110 V, and Voltage Protection Level ( Up): 160 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OVR 15E
ABB OVR 15E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 15 V, and Voltage Protection Level ( Up): 25.5 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OVR 180E
ABB OVR 180E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 180 V, and Voltage Protection Level ( Up): 203 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OVR 30E
ABB OVR 30E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 30 V, and Voltage Protection Level ( Up): 43.5 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OVR 50E
ABB OVR 50E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 50 V, and Voltage Protection Level ( Up): 65.0 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OVR PV T1-T2 10-1500 C QS
The ABB OVR PV T1-T2 10-1500 C QS is a DIN-rail mounted surge protective device for photovoltaic systems, intended to protect systems against transient overvoltage (lightning). It has a rated voltage (Ur) of 1500 V DC, a voltage protection level (Up) of 5 kV, and an arrester class of I II. Discharge current ratings are nominal (8/20 µs) 20 kA, maximum (8/20 µs) 40 kA, and total (10/350 µs) 10 kA. Rated service short-circuit breaking capacity (Ics) is 11 kA. It provides two protected poles and two conductors, a plug-in version with status indicator, IP20 protection, and dimensions of 24 mm width, 45 mm height, and 74 mm depth, weighing 0.130 kg. Standards: IEC 61 643-11 / EN 50539-11 / UL 1449 4th ed.
- OVR PV T1-T2 10-1500 P QS
The ABB OVR PV T1-T2 10-1500 P QS is a surge protective device for photovoltaic systems, intended to protect equipment against transient overvoltages from lightning. It is rated 1500 V DC with a voltage protection level (Up) of 5 kV and maximum continuous operating voltage (Uc) of 1500 V at L-PE and L-L. Discharge current ratings include nominal 20 kA (8/20 µs), maximum 30 kA (8/20 µs), and total 10 kA (10/350 µs); impulse current is 5 kA (10/350 µs) per pole and 10 kA total (10/350 µs). It has arrester class I II, two protected poles, three poles, and three modular spacings. Mounting is DIN-rail, version is plug-in, degree of protection is IP20, and dimensions are 64 mm width, 96 mm height, 84 mm depth, 0.488 kg.
- OVR PV T1-T2 10-1500 P TS QS
The ABB OVR PV T1-T2 10-1500 P TS QS is a DIN-rail mounted surge protective device for photovoltaic systems, intended to protect equipment against transient overvoltage from lightning. It is a Type I+II arrester with two protected poles, three poles, and two conductors, rated 1500 V DC. Nominal discharge current is 20 kA (8/20 µs), maximum discharge current 30 kA (8/20 µs), and total impulse current 10 kA (10/350 µs). Voltage protection level Up is 5 kV. It is a plug-in version with a status indicator, IP20 protection, and 3 modular spacings (64 mm wide). Standards: IEC 61643-11, EN 50539-11, and UL 1449 4th edition.