- ESP PCB/110D
ABB data SPD, product main type Data SPD, display model ESP PCB/110D, manufacturer ID 7TCA085400R0040. This three-pole surge protective device is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. It is rated for a nominal AC system voltage (Uo) of 110 V, a maximum continuous operating voltage (Uc) of 132 V, and a voltage protection level (Up) of 145 V. Rated current (In) is 300 mA, rated frequency (f) is 9 MHz, and discharge current I(max, 8/20 µs) is 10 kA. Serial resistance is 9.4 ohms. Connection type is soldered. Ambient air temperature for operation is -40 to +80 °C. Dimensions are 30 mm width, 30 mm height, and 30 mm depth; net weight is 0.01 kg. Standards: IEC 61643-21.
- ESP PCB/110E
ABB ESP PCB/110E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 110 V, and Voltage Protection Level ( Up): 160 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP PCB/15D
ABB ESP PCB/15D is a data surge protective device (SPD) for protecting systems against transient overvoltages or surges from lightning and electrical switching events. It is manufactured under ID 7TCA085400R0042 and complies with IEC 61643-21. The nominal AC system voltage (Uo) is 15 V, maximum continuous operating voltage (Uc) is 19 V, and voltage protection level (Up) is 23 V. Rated current (In) is 300 mA, rated frequency (f) is 2.5 MHz, and maximum discharge current I(max, 8/20 µs) is 10 kA. It has three protected poles, soldered connection, and 9.4 ohm serial resistance. Operating ambient air temperature is -40 to +80 °C. Dimensions are 30 mm width, 30 mm height, and 30 mm depth; net weight is 0.01 kg.
- ESP PCB/15E
ABB ESP PCB/15E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 15 V, and Voltage Protection Level ( Up): 25.5 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP PCB/30D
ABB ESP PCB/30D is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 30 V, and Voltage Protection Level ( Up): 42.5 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP PCB/30E
ABB ESP PCB/30E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 30 V, and Voltage Protection Level ( Up): 43.5 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP PCB/50D
ABB ESP PCB/50D is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 50 V, and Voltage Protection Level ( Up): 73 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP PCB/50E
ABB ESP PCB/50E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 50 V, and Voltage Protection Level ( Up): 65 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.