- ESN40
ABB ESN40 is a black polyamide/nylon conduit end sleeve, manufacturer ID 7TCA298010R0448. It provides protection to the end of conduit systems cable breakout facility in situations where sealing is not required. The sleeve fits conduit size NC40/NW36. ETIM 8 classification is EC000879 (cable entry sleeve); UNSPSC is 39121404. The product contains no batteries.
- ESP 06D/2BX
ABB Data SPD surge protective device, model ESP 06D/2BX, manufacturer ID 7TCA085400R0080. It is intended to protect systems against transient overvoltages or surges from lightning and electrical switching events. The nominal AC system voltage is 6 V, with a maximum continuous operating voltage of 7.79 V and a voltage protection level of 10 V. Rated current is 300 mA, rated frequency is 800 kHz, and maximum discharge current is 10 kA at 8/20 µs. Serial resistance is 9.4 Ω. Connection is by screw clamp with an 8 mm wire stripping length. Operating ambient air temperature is -40 to +80 °C. Dimensions are 170 mm width, 80 mm height, and 56 mm depth; net weight is 0.300 kg. Standards: IEC 61643-21.
- ESP 06D/BX
ABB ESP 06D/BX is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 6 V, and Voltage Protection Level ( Up): 10 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 06D/BX/I
ABB ESP 06D/BX/I is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 6 V, and Voltage Protection Level ( Up): 10 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 06E
ABB ESP 06E is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 6 V, and Voltage Protection Level ( Up): 16 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 06F
ABB ESP 06F is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 6 V, and Voltage Protection Level ( Up): 10 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 06H
ABB ESP 06H is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Voltage Protection Level ( Up): 10.5 V, and Maximum Continuous Operating Voltage (U c ): 7.79 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- ESP 06Q
ABB ESP 06Q is an industrial catalog item. Key specifications include Standards: IEC 61643-21, Suitable For: To protect systems against transient overvoltages or surges from lightning and e, Nominal AC Voltage of the System (U o ): 6 V, and Voltage Protection Level ( Up): 10 V. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.