- 150-F108NCRB
The Rockwell 150-F108NCRB is an SMC Flex soft starter for three-phase motors, rated 108 A and 20-75 Hp at 460 V AC. It operates at 200...600 V AC (-15%, +10%) per UL/CSA/NEMA and 50/60 Hz, with 24 V AC/DC control. Line-connected motor current is 27...108 A at 600/Y/690 V AC, three-phase; delta-connected current is 47...187 A at 500/575 V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current at 117% of motor FLC. Control options include pump control, and a display is fitted. The open-type unit has three poles, internal bypass, and dimensions of 196.4 mm width, 212.2 mm depth and 443.7 mm height.
- 150-F108NCRD
The Rockwell 150-F108NCRD is an SMC Flex soft starter with an open-type enclosure, three poles, and a display. It operates on 24 V AC/DC control voltage and a rated operational voltage of 200...600 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit. Controller rating is 108 A, 20-75 Hp at 460 V AC. Line-connected motor current is 27...108 A at 600/Y/690 V AC, 3-phase; delta-connected motor current is 47...187 A at 500/575 V AC, 3-phase. It provides integrated motor overload protection, internal bypass, and programmable NO/NC auxiliary contacts. Steady-state heat dissipation with control and fan power is 91 W. Operating temperature is -5 to 50 degrees C open. Dimensions are 196.4 mm width, 212.2 mm depth, and 443.7 mm height.
- 150-F108NZDB
The Rockwell 150-F108NZDB is an SMC Flex smart motor controller configured as a soft starter with an integrated display and internal bypass. The controller rating is 108 A, 20–75 Hp at 460V AC, with line-connected motor current of 27...108 A at 600/Y/690V AC, 3-phase, and delta-connected motor current of 47...187 A at 500/575V AC, 3-phase. Control voltage is 100...240V AC. The power circuit is rated 230...690V/Y (-15%, +10%) per IEC, with operating frequency 50/60 Hz and rated impulse voltage 6000V per IEC. It provides integrated motor overload protection, trip classes 10, 15, 20 and 30, and pump control. Dimensions are 196.4 mm wide, 212.2 mm deep, and 443.7 mm high.
- 150-F108NZDD
The Rockwell Allen-Bradley 150-F108NZDD is a soft starter in the Smart Motor Controller category, supplied with a display. Its controller rating is 108 A, 20–75 Hp at 460 V AC. Control voltage is 100...240 V AC, and the rated operating voltage Ue is 230 V. The transformer control module is rated 75 VA at 100...240 V AC (-15%, +10%). Overload current is 27 A for line-connected devices and 47 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Power-circuit operating frequency is 50/60 Hz. Control options include brake control.
- 150-F1250NBA
The Rockwell 150-F1250NBA is an SMC Flex solid-state soft starter rated 1250 A and 1000 Hp at 460V AC. It operates on three-phase 200–460V AC with a 230–240V AC control voltage and 50/60 Hz power-circuit operating frequency. Overload current is 416 A for line-connected devices and 533 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Maximum line-connected motor power is 900 kW at 500V AC, 50 Hz, three-phase; maximum delta-connected motor power is 900 kW at 400/415V AC, 50 Hz, three-phase. A display is included. Power-circuit DV/DT protection uses an RC snubber network, and repetitive peak inverse voltage rating is 1400V per UL/CSA/NEMA.
- 150-F1250NBAB
The Rockwell 150-F1250NBAB is an SMC Flex soft starter with a rated controller current of 1250 A and 1000 HP at 460 V AC. It operates on 200...480 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit at 50/60 Hz, with control voltage of 230...240 V AC. The open-type device includes an internal bypass, an LCD and keypad, integrated motor overload protection, and trip classes 10, 15, 20, and 30. Power circuit protection includes an RC snubber network, 6000 V rated impulse voltage per IEC, and 2500 V dielectric withstand per IEC. Dimensions are 596.9 mm wide, 346.2 mm deep, and 1041.1 mm high.
- 150-F1250NCA
The Rockwell 150-F1250NCA is an SMC Flex soft starter with a 1250 A, 1000 Hp at 460 V AC controller rating and an integrated display. It operates on 230...240 V AC control voltage and supports 50/60 Hz power circuits. Line-connected motor current is 416...1250 A at 600/Y/690 V AC, three-phase; delta-connected motor current is 533...1600 A at 500/575 V AC, three-phase. Overload current is 416 A line-connected and 533 A delta-connected. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor full-load current. The open-type device measures 596.9 mm wide, 346.2 mm deep, and 1041.1 mm high, with an operating temperature range of -5 to 50 degrees Celsius.
- 150-F1250NCAB
The Rockwell 150-F1250NCAB is an SMC Flex soft starter rated 1250 A and 1000 Hp at 460 V AC. It operates from a 230...240 V AC control supply at 50/60 Hz and includes a display. The controller provides pump control and trip classes 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Overload current is 416 A for line-connected devices and 533 A for delta-connected devices. Maximum line-connected motor power is 900 kW at 500 V AC, 50 Hz, three-phase; maximum delta-connected motor power is 900 kW at 400/415 V AC, 50 Hz, three-phase. Power circuit protection includes an RC snubber network for DV/DT and a repetitive peak inverse voltage rating of 1600 V per UL/CSA/NEMA.