- AF205-40-00-11
ABB AF205-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 1000 V in the main circuit at 60 Hz. Conventional free-air thermal current is 350 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, 132 kW at 440 V, and 55 kW at 220/230/240 V. Dimensions are 140 mm wide, 152.5 mm deep, and 196 mm high; net weight is 3.3 kg. Short-circuit protection uses gG type fuses rated 400 A.
- AF205-40-00-12
The ABB AF205-40-00-12 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 275 A at 1000 V and 40 °C, 250 A at 1000 V and 60 °C, and 200 A at 1000 V and 70 °C. Rated operational current AC-3 is 205 A at 415 V and 55 °C. Rated operational power AC-3 is 110 kW at 415 V and 132 kW at 440 V. Dimensions are 140 mm wide, 152.5 mm deep, and 196 mm high, with a net weight of 3.3 kg.
- AF205-40-00-14
The ABB AF205-40-00-14 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 140 mm wide, 152.5 mm deep, and 196 mm high, and weighs 3.3 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 275 A at 1000 V and 40 °C, and 350 A at 690 V and 40 °C. Rated operational current AC-3 is 205 A at 380/400 V and 55 °C. Rated operational power AC-3 is 110 kW at 380/400 V and 132 kW at 440 V. Short-circuit protection uses gG type fuses rated 400 A.
- AF205-40-11-11
The ABB AF205-40-11-11 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 205 A at 415 V, 440 V, and 380/400 V, all at 55 °C. Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, and 132 kW at 440 V. Conventional free-air thermal current Ith is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Main terminals are bars; dimensions are 140 mm wide, 152.5 mm deep, and 195.6 mm high, weighing 3.3 kg.
- AF205-40-11-12
The ABB AF205-40-11-12 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 350 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 205 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, 132 kW at 440 V, and 55 kW at 220/230/240 V. The coil operates from 48 to 130 V AC at 50 Hz or 60 Hz and 48 to 130 V DC. Dimensions are 140 mm wide, 152.5 mm deep, and 195.6 mm high; net weight is 3.3 kg.
- AF205-40-11-13
ABB AF205-40-11-13 AC contactor, manufacturer ID 1SFL527102R1311. Four-pole IEC contactor with four main contacts NO, no main contacts NC, and one auxiliary contact NO plus one NC. Main circuit rated operational voltage 1000 V at 50 Hz. Rated operational current AC-3 is 205 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, 132 kW at 440 V, and 55 kW at 220/230/240 V. Coil control voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 140 mm wide, 152.5 mm deep, and 195.6 mm high, weighing 3.3 kg.
- AF205-40-11-14
The ABB AF205-40-11-14 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 50 Hz. Rated operational current AC-3 is 205 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 110 kW at 380/400 V and 415 V, 132 kW at 440 V, and 55 kW at 220/230/240 V. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 140 mm wide, 152.5 mm deep, and 195.6 mm high; net weight 3.3 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF205-40-22-11
The ABB AF205-40-22-11 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 152.5 mm deep, and 196 mm high, and weighs 3.3 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 110 kW at 380/400 V and 415 V, 132 kW at 440 V, and 55 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 400 A.