- OT800ERRR6TZ
ABB OT800ERRR6TZ is a six-pole isolating switch in a stainless steel enclosure, identified by manufacturer ID 1SCA102334R1001. The enclosure measures 800 mm wide, 1000 mm high, and 230 mm deep, and weighs 52.8 kg. It provides IP65 protection according to IEC 60529 and IK09 impact resistance for the housing, with pollution degree 3. Conventional thermal current (Ithe) is 720 A fully enclosed. Cable entry is top or bottom, with eight ring-flange cable outlets per side at 25.5 mm diameter. Main circuit connection uses 12 mm hole diameter screw clamps; the PE terminal accepts 16 pieces, 25 to 120 mm². A stainless steel pistol handle is fitted. Auxiliary contacts comprise 4 NO and 2 NC mounted, with a maximum of 4 NO and 4 NC.
- OT800ES30
The ABB OT800ES30 is a 3-pole, side-operated switch-disconnector for low-voltage circuits. It is rated 800 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power at AC-23A is 250 kW at 220 to 240 V, 450 kW at 400 to 415 V, 560 kW at 500 V, and 800 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 20 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 316 mm wide, 250 mm high, and 130 mm deep, weighing 7 kg. Terminal type is lug terminals; handle and shaft are not included.
- OT800ES40
ABB OT800ES40 is a 4-pole, side-operated switch-disconnector with base mounting. The fourth pole is on the right side and is switched with simultaneous function. Rated insulation voltage is 1000 V according to IEC/EN 60664-1; rated impulse withstand voltage is 12 kV. Conventional free-air thermal current Ith is 800 A at 40 °C, and conventional thermal current Ithe is 800 A fully enclosed. Rated operational current AC-21A, AC-22A, and AC-23A is 800 A at 380 to 415 V, 500 V, and 690 V. Rated short-circuit making capacity is 80 kA at 690 V; short-time withstand current Icw is 20 kA for 1 s. Power loss is 40 W per pole at rated operating conditions. Dimensions are 381 mm width, 250 mm height, 130 mm depth; net weight 8.5 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OT800ESUR3TZ
ABB OT800ESUR3TZ is a three-pole isolating switch in a stainless steel enclosure with a pistol handle. It is rated for a conventional thermal current (Ithe) of 720 A fully enclosed. The enclosure provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09. Insulation voltage is 1000 V, with pollution degree 3. Dimensions are 800 mm wide, 1000 mm high, and 330 mm deep; net weight is 49.8 kg. Cable entry is bottom/bottom, with blank or 8x ring-flange plus 25.5 mm outlets per side. Main circuit connection uses 12 mm hole diameter screw clamps; PE terminal accommodates 8 pieces, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC.
- OT800ETRR3AZ
ABB OT800ETRR3AZ is an isolating switch in a steel sheet enclosure with a pistol handle in red/yellow. It provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09 for the housing, with pollution degree 3. The conventional thermal current (Ithe) is 720 A fully enclosed. Cable entry is top or bottom, with four ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 12 mm hole diameter screw clamp; PE terminal capacity is 4 pc, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal. Dimensions are 400 mm wide, 1000 mm high, and 230 mm deep; net weight 28.51 kg.
- OT800ETRR3TZ
ABB isolating switch OT800ETRR3TZ, manufacturer ID 1SCA022828R1770, supplied in a steel sheet enclosure rated IP65 according to IEC 60529 and IK09 for impact resistance, with pollution degree 3. Conventional thermal current Ithe is 720 A in the fully enclosed configuration. The enclosure measures 400 mm wide, 1000 mm high, and 230 mm deep, and weighs 29.31 kg. Cable entry is top or bottom, with four ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 12 mm hole diameter screw clamp; PE terminal capacity is 4 pc, 25 to 120 mm². A black pistol handle is fitted. Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal is provided.
- OT800ETRR6AZ
The ABB OT800ETRR6AZ is an enclosed isolating switch-disconnector with a steel sheet enclosure measuring 800 mm wide, 1000 mm high, and 230 mm deep, weighing 49.8 kg. It provides IP65 protection according to IEC 60529 and IK09 housing impact resistance, with pollution degree 3. The six-pole main circuit is rated 1000 V, with conventional thermal current 720 A fully enclosed and rated operational current AC-22A and AC-23A of 720 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 400 kW at 380 to 415 V, 500 kW at 500 V, and 710 kW at 690 V. It includes four NO and two NC mounted auxiliary contacts, a pistol handle in red/yellow, and cable entry at top or bottom. Standards: IEC 60947-1, -3.
- OT800ETRR6TZ
ABB OT800ETRR6TZ is an enclosed isolating switch in a steel sheet enclosure with a black pistol handle. It is rated IP65 according to IEC 60529 and has a pollution degree of 3 and housing impact resistance IK09. Conventional thermal current (Ithe) is 720 A fully enclosed. The enclosure measures 800 mm wide, 1000 mm high, and 230 mm deep, and weighs 49.2 kg. Cable entry is top or bottom, with 8 ring-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Main circuit connection uses a 12 mm hole diameter screw clamp; PE terminal accepts 16 pc, 25 to 120 mm². Mounted auxiliary contacts are 4 NO and 2 NC, with a maximum of 4 NO and 4 NC. No neutral terminal.