- 140G-M6S4-D80-SJ-CJ
The Rockwell 140G-M6S4-D80-SJ-CJ is a molded case switch (isolator) with a rated permanent current Iu of 800 A and four poles. It uses a toggle control element and screw connections on the front side. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity is 70 kA at 400...415 V AC, 50/60 Hz per IEC 60947-2. Rated impulse withstand voltage is 8 kV; insulation voltage is rated 1000 V per IEC. Degree of protection is IP40. Dimensions are 280 mm wide, 268 mm high, and 103.5 mm deep. It is a built-in fixed device, not repairable, and not stocked.
- 140G-M6X3
The Rockwell 140G-M6X3 is a motor protection circuit breaker supplied as a frame only, with thermal magnetic or electronic protection. Its rated current is 800 A. It is a three-pole device. The unit is not repairable. Standards compliance is listed as UL489, CSA22.2 No. 5, and IEC. Dimensions are 28.6 cm height, 30.505 cm width, and 36.5 cm length, with a weight of 8.58 kg. The breaker is stocked. Lead time is 5. Preferred availability and quick turnaround are both false.
- 140G-M6X4
The Rockwell 140G-M6X4 is a motor protection circuit breaker rated 800 A. It is UL Listed, CSA Certified, CE, and CCC. Dimensions are 30.023 mm high, 31.013 mm wide, and 37.008 mm long, with a weight of 10.832 kg. The unit is not repairable.
- 140G-MTF3-D60
The Rockwell 140G-MTF3-D60 is a motor protection circuit breaker with adjustable thermal and adjustable magnetic trip settings. It provides thermal-magnetic protection and has a trip unit rating of 600A. It is UL Listed, CSA Certified, CE marked, and CCC marked, and complies with UL489, CSA22.2 No. 5, and IEC. Dimensions are 18.49 height, 12.9 width, and 23.19 length. It is not repairable.
- 140G-MTF3-D80
The Rockwell 140G-MTF3-D80 is a 3-pole molded case circuit breaker in the M-Frame with an 800 A rating and an 800 A trip unit. It provides thermal-magnetic protection with adjustable thermal and adjustable magnetic settings. The breaker is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 23.393 cm length, 18.796 cm width, and 12.09 cm height; weight is 1.576 kg. The unit is not repairable and is non-stocked.
- 140G-MTF4-D60
Rockwell motor protection circuit breaker, model 140G-MTF4-D60, is an M-Frame thermal-magnetic trip unit with adjustable thermal and adjustable magnetic protection. It is rated 800 A. Certifications listed are UL Listed, CSA Certified, CE, and CCC. The unit is not repairable. Dimensions are 30.0 cm length, 15.999 cm width, and 15.001 cm height; weight is 1.79 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false, with a listed lead time of 5. No manufacturer part number or order code is supplied in the authoritative data.
- 140G-MTF4-D80
The Rockwell 140G-MTF4-D80 is a motor protection circuit breaker with a thermal magnetic trip unit rated 800 A in the M-Frame size. It is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 30.0 cm length, 15.999 cm width, and 15.001 cm height; weight is 1.95 kg. The unit is not repairable. It is non-stocked, is not marked for preferred availability or quick turnaround, and has a stated lead time of 42.
- 140G-MTH3-D60
The Rockwell 140G-MTH3-D60 is an electronic motor protection circuit breaker with an LSI trip unit rated 600 A. It is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 16.51 mm high, 16.51 mm wide, and 32.385 mm long. The unit is not repairable.