150-C3NBR
Material Number
—
Manufacturer
ROCKWELL
Product ID
108929

Get a Free Quote

Request pricing and availability for 150-C3NBR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated control power during start with fan
215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
0.905
See all specifications

Product Highlights

  1. Control and Protection: SMC-3 smart motor controller with integrated motor overload protection, selectable trip class 10, 15, or 20, and selectable current limit of 150%, 250%, 350%, or 450% of full load current
  2. Starting and Stopping: Single-direction operation with selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, selectable initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, selectable kick start at 450% FLA for 0, 0.5, 1.0, or 1.5 s, and soft stop
  3. Control Supply: 24 V AC/DC control supply voltage, with rated control power during start of 580 mA at 24 V AC and 705 mA at 24 V DC without fan, or 660 mA at 24 V AC and 800 mA at 24 V DC with fan
  4. Power Circuit Ratings: 200 V rated operating voltage, 250 V AC/30 V DC rated operational voltage for side mount auxiliary contacts, 600 V AC insulation voltage per UL/CSA/NEMA, 6 kV rated impulse voltage, 2500 V AC dielectric withstand per IEC, and 1400 V repetitive peak voltage per UL/CSA/NEMA
  5. Auxiliary Contacts: TB-97 and TB-98 overload/fault contacts, one normally open electromagnetic relay contact rated 1 A conventional thermal current, 0.6 A at 120 V AC and 0.3 A at 240 V AC, with 432 VA make and 72 VA break
  6. Physical and Environmental: Open-type 3-phase controller, IP2X degree of protection, 44.8 mm width, 110 mm depth, 139.7 mm height, 0.905 kg weight, operating temperature -5 to 50 °C, humidity 5 to 95% noncondensing, altitude up to 2000 m, and pollution degree 2
  7. Compliance and Protection: Type 1 short-circuit protection device performance, standard available fault current up to 5 kA at maximum standard fuse 15 A, high capacity available fault current up to 69 kA at 600 V with maximum 10 A time delay Class J or Class L fuse for inside delta connected motors, and EMC radiated emission Class A per IEC
150-C3NBR

Product Information

Technical Specifications

Specifications for 150-C3NBR

ParameterValue
Product FamilySMC-3
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Overload current1 A
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max69kA @ 600V, maximum current 10 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max5 kA @ maximum standard fuse 15 A for delta device opsal current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
ParameterValue
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight0.905
ShockOpsal: 15 G
Width44.8 mm (1.76 in)
Depth110 mm (4.33 in)
Height139.7 mm (5.5 in)
Cable size2.5...25 mm2 (14...4 AWG) for line power terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation11 W
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Mounting hole size4.6 mm
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height9.093
Lead Time5
Dimension Width18.491
Dimension Length17.602
Stock StatusSTOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Allen-Bradley 150-C3NBR Smart Motor Controller