- 140G-G2C3-D12-UJ
The Rockwell 140G-G2C3-D12-UJ is a motor protection circuit breaker rated 125 A. It measures 13.4 cm high, 9.2 cm wide, and 14.6 cm long, and weighs 1.244 kg. The unit is not repairable.
- 140G-G2C4-C16
The Rockwell 140G-G2C4-C16 is a G-frame motor protection circuit breaker rated 125 A with thermal magnetic protection. Its IEC breaking capacity is 36 kA at 415 V. The unit is not repairable. Dimensions are 13.335 mm height, 12.954 mm width, and 14.351 mm length, with a weight of 1.481 kg.
- 140G-G2C4-C20
The Rockwell 140G-G2C4-C20 is a motor protection circuit breaker with a fixed thermal and fixed magnetic trip unit. It is rated 125 A and provides thermal magnetic protection. The device is UL Listed, CSA Certified, CE marked, and CCC certified. It is not repairable. Dimensions are 13.335 mm high, 14.097 mm wide, and 12.954 mm long.
- 140G-G2C4-C25
The Rockwell 140G-G2C4-C25 is a motor protection circuit breaker with thermal magnetic protection and a fixed thermal, fixed magnetic adjustment type. Its trip unit rating is 25 A, and its current rating is 125 A. The device is not repairable. Dimensions are 13.0 height, 11.999 width, and 14.0 length.
- 140G-G2C4-C30
Product identification: ROCKWELL 140G-G2C4-C30. The 140G-G2C4-C30 is a thermal-magnetic motor protection circuit breaker with fixed thermal and fixed magnetic adjustment. It has a 30 A trip unit rating, an IEC breaking capacity of 36 kA at 415 V, and a UL interrupting rating of 25 kA at 480 V. Dimensions are 13.335 height, 13.081 width, and 15.113 length. It is not repairable.
- 140G-G2C4-C32
The Rockwell 140G-G2C4-C32 is a 4-pole motor protection circuit breaker in the G-frame, rated 125 A, with a 32 A trip unit. It uses a fixed thermal/fixed magnetic trip unit and thermal-magnetic protection. Interrupting capacity is 25 kA at 480 V. The breaker is not repairable. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 13.0 cm high, 13.2 cm wide, and 14.501 cm long; weight is 1.5 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false. Lead time is 42.
- 140G-G2C4-C35
The Rockwell 140G-G2C4-C35 is a 4-pole motor protection circuit breaker with thermal-magnetic protection and a fixed thermal/fixed magnetic adjustment type. It has a trip unit rating of 35 A and a current rating of 125 A. IEC breaking capacity is 36 kA at 415 V. Dimensions are 13.335 mm height, 12.954 mm width, and 14.351 mm length. The device is not repairable.
- 140G-G2C4-C35-KA
The ROCKWELL 140G-G2C4-C35-KA is a motor protection circuit breaker rated 125 A. It uses a fixed thermal/magnetic trip unit. The breaker is not repairable. Dimensions are 0.0 cm height, 0.0 cm width, and 0.0 cm length, with a weight of 0.999 kg. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 15.