- 140G-R12K3-E25-Z1
The Rockwell 140G-R12K3-E25-Z1 is an R-frame molded case circuit breaker rated 2500 A with an LSIG-MM electronic trip unit, 100% rated. It provides electronic protection with LSIG-MM magnetic trip. Interrupting rating is 125 kA at 480 V. The breaker is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 70.5 cm length, 49.0 cm width, and 58.0 cm height; weight is 139.0 kg. The unit is not repairable, is non-stocked, and has a lead time of 5. It is not marked for preferred availability or quick turnaround.
- 140G-R12K3-E25-Z1-W1-UJ-DA
Rockwell motor protection circuit breaker, model 140G-R12K3-E25-Z1-W1-UJ-DA. Current rating: 3000 A. The unit is not repairable. Dimensions are 58.0 cm height, 68.0 cm width, and 70.0 cm length; weight is 129.0 kg. Preferred availability and quick turnaround are both false, and stock status is non-stocked, with a lead time of 15. No trip unit type, certification, or application data is supplied in the authoritative parameters.
- 140G-R12K3-E30
The Rockwell 140G-R12K3-E30 is a 3000 A R-Frame molded case circuit breaker with a 3-pole configuration and an LSIG-MM electronic trip unit. Its UL interrupting rating is 125 kA at 480 V. The breaker complies with UL489, CSA22.2 No. 5, and IEC 60947-2, and holds UL Listed, CSA Certified, CE, and CCC certifications. Dimensions are 71.0 cm length, 68.5 cm width, and 58.5 cm height; weight is 127.0 kg. The unit is not repairable and is non-stocked. Lead time is 31 days. Preferred availability and quick turnaround are both false.
- 140G-R12K3-E30-DA
The Rockwell 140G-R12K3-E30-DA is a motor protection circuit breaker rated 3000 A, equipped with an LSIG-MM electronic trip unit. It is not repairable. The unit weighs 0.999 kg. This product is non-stocked.
- 140G-R12K3-E30-MJ-RJ
The Rockwell 140G-R12K3-E30-MJ-RJ is a three-pole molded case circuit breaker with a rated permanent current of 3000 A and an R frame. It uses an electronic LSIG protection unit providing long-time, short-time, high instantaneous, ground fault, and maintenance instantaneous protection, with integrated earth fault protection. Rated impulse withstand voltage is 12 kV, insulation voltage is rated 1000 V per IEC, and watt loss is 351 W. Interrupting ratings include 80 kA at 440 V AC, 50/60 Hz per IEC 60947-2, and 125 kA at 480 V, 50/60 Hz per NEMA/UL 489/CSA C22.2. Control is by push button, with a 24...30 V AC/DC spring charging motor and 24 V AC/DC shunt-trip and shunt-close. Electrical life is 60 operations per hour at 415 V AC.
- 140G-R12K3-E30-Z1
The Rockwell 140G-R12K3-E30-Z1 is a 3000 A, R-Frame motor protection circuit breaker with a 3-pole configuration and electronic protection. It uses an LSIG-MM adjustment type and is 100% rated. The UL interrupting rating is 125 kA at 480 V. The breaker complies with UL489, CSA22.2 No. 5, and IEC 60947-2, and holds UL Listed, CSA Certified, CE, and CCC certifications. It is not repairable. Dimensions are 66.5 cm height, 52.5 cm width, and 69.5 cm length, with a weight of 116.5 kg. The unit is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 42.
- 140G-R12K4-E25-Z1-W1
The Rockwell 140G-R12K4-E25-Z1-W1 is an electronic motor protection circuit breaker in the R-Frame with a 2500 A rating. It uses LSIG-MM adjustment, is 100% rated, and has no interlocking. Protection is electronic. The UL interrupting rating is 125 kA at 480 V. It is certified to UL489, CSA22.2 No. 5, and IEC 60947-2, and carries UL Listed, CSA Certified, CE, and CCC certifications. Dimensions are 47.5 cm height, 65.0 cm width, and 69.5 cm length; weight is 104.0 kg. The unit is not repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 34.
- 140G-R12K4-E30
The Rockwell 140G-R12K4-E30 is a 3000 A R-Frame molded case circuit breaker with electronic protection and an LSIG-MM magnetic trip adjustment type. It carries UL Listed, CSA Certified, CE, and CCC certifications and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. The UL interrupting rating is 125 kA at 480 V. Dimensions are 70.0 cm height, 67.0 cm width, and 70.0 cm length; weight is 160.0 kg. The unit is not repairable and is non-stocked, with a lead time of 34 days. It is not marked for preferred availability or quick turnaround.