- 140G-I2C4-D16
The Rockwell 140G-I2C4-D16 is a molded case motor protection circuit breaker with a 225 A, I-Frame rating and a 160 A trip unit. It uses a thermal-magnetic protection type with fixed thermal and fixed magnetic adjustment. The UL interrupting rating is 25 kA at 480 V. It is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 15.999 cm high, 17.3 cm wide, and 21.801 cm long; weight is 2.3 kg. The device is not repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 25.
- 140G-I2C4-D20
The Rockwell 140G-I2C4-D20 is a four-pole molded case circuit breaker in the I-frame size with a 225 A rating and a 200 A trip unit. It uses fixed thermal and fixed magnetic adjustment. Interrupting ratings are 36 kA at 415 V per IEC and 25 kA at 480 V per UL. Certifications include UL Listed, CSA Certified, CE, and CCC. Dimensions are 15.601 cm high, 17.3 cm wide, and 21.501 cm long; weight is 2.302 kg. The unit is not repairable. It is non-stocked, not marked for preferred availability or quick turnaround, and has a stated lead time of 25.
- 140G-I2C4-D22
The Rockwell 140G-I2C4-D22 is a molded case motor protection circuit breaker with a 225 A trip unit rating and I-frame size. It uses thermal-magnetic protection and has a 4-pole configuration. IEC breaking capacity is 36 kA at 415 V. The breaker is UL Listed, CSA Certified, CE marked, and CCC marked, and it complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 21.999 cm length, 17.501 cm width, and 15.499 cm height; weight is 2.287 kg. It is not repairable, is non-stocked, and has a lead time of 52. Preferred availability and quick turnaround are false.
- 140G-I2C4-D22-SJ-AJ
The Rockwell 140G-I2C4-D22-SJ-AJ is a motor protection circuit breaker rated 225 A. It is not repairable. The unit weighs 0.999 kg. No interrupting rating, trip unit configuration, certification, or dimensional data is stated for this model.
- 140G-I3C3-C60
Product identification: ROCKWELL 140G-I3C3-C60. The 140G-I3C3-C60 is a thermal-magnetic motor protection circuit breaker with a fixed thermal and fixed magnetic adjustment type. It has a 60 A trip unit rating, a 50 kA breaking capacity at 415 V per IEC, and a 35 kA interrupting rating at 480 V per UL. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 15.621 height by 16.256 width.
- 140G-I3C3-C60-SJ
The 140G-I3C3-C60-SJ is a three-pole motor protection circuit breaker from Rockwell. It is rated for 24 V AC/DC and has a breaking capacity of 35 kA at 480 V. The device is non-repairable and is not stocked. It is intended for industrial applications.
- 140G-I3C3-C63
The ROCKWELL 140G-I3C3-C63 is a thermal-magnetic motor protection circuit breaker with a 63 A trip unit rating and 225 A current rating. It provides 50 kA IEC breaking capacity at 415 V and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 19.0 mm height, 15.5 mm width, and 15.5 mm length. The device is not repairable.
- 140G-I3C3-C70
The Rockwell 140G-I3C3-C70 is a molded case motor protection circuit breaker with a 70 A trip unit rating. It uses fixed thermal and fixed magnetic adjustment and provides thermal magnetic protection. Interrupting ratings are 50 kA at 415 V per IEC and 35 kA at 480 V per UL. The breaker is marked to UL489, CSA22.2 No. 5, and IEC 60947-2. It is not repairable. Dimensions are 15.621 cm height, 16.51 cm width, and 19.05 cm length; weight is 1.74 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false.