- GAXVE1RNEXRF4XCW
ABB GAXVE1RNEXRF4XCW is an industrial catalog item. Key specifications include Product Net Height: 9-3/16 in, Product Net Depth / Length: 13-1/4 in, Product Net Width: 3-7/8 in, and Product Net Weight: 7.499205 lb 3.401 kg. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- UA110-30-00-26
The ABB UA110-30-00-26 is a three-phase AC contactor for capacitor duty, identified by manufacturer ID 1SFL451022R2600. It has three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, and 75 kvar at 400/415 V and 40 °C. Maximum electrical switching frequency is 240 cycles per hour; mechanical durability is 10 million operations. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high, weighing 1.8 kg.
- UA110-30-00-36
ABB UA110-30-00-36 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 50/60 Hz across 40 °C and 55 °C, and 35 kvar at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg. Manufacturer ID: 1SFL451022R3600.
- UA110-30-00-42
ABB UA110-30-00-42 AC contactor, manufacturer ID 1SFL451022R4200. Three main contacts, normally open, with no auxiliary contacts. Rated operational voltage for the main circuit is 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 230/240 V and 55 °C, 35 kvar at 230/240 V and 70 °C, and 75 kvar at 400/415 V and 40 °C, all at 50/60 Hz. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.8 kg.
- UA110-30-00-80
The ABB UA110-30-00-80 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 75 kvar at 400/415 V, both at 40 °C and 50/60 Hz. Maximum electrical switching frequency is 240 cycles per hour; mechanical durability is 10 million operations.
- UA110-30-00-81
The ABB UA110-30-00-81 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA, and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V, 50/60 Hz, at 40 °C and 55 °C, and 35 kvar at 70 °C. Mechanical durability is 10 million operations.
- UA110-30-00-83
The ABB UA110-30-00-83 is a three-pole AC contactor for capacitor switching, identified by manufacturer ID 1SFL451022R8300. It has three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg. Mechanical durability is 10 million operations.
- UA110-30-00-84
The ABB UA110-30-00-84 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V in the main circuit and a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power for AC-6b is 40 kvar at 230/240 V and 40 °C, 50/60 Hz. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.