Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 2080-MOT-HSC High-Speed Counter Module

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ROCKWELL 2080-MOT-HSC?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 2080-MOT-HSC cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2080-MOT-HSC
Material Number
—
Manufacturer
ROCKWELL
Product ID
108085

Get a Free Quote

Request pricing and availability for 2080-MOT-HSC.

More parts to source? Send your whole list in one enquiry

Key specifications

Type of voltage (input voltage)
DC
Type of output voltage
DC
Short-circuit protection, outputs available
No
Operating temperature
-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Input frequency, max
250 kHz (50% duty)
Weight
52.163
See all specifications

Product Highlights

  1. Counter Input: One quadrature (ABZ) differential input with a maximum frequency of 250 kHz at 50% duty cycle, minimum pulse width of 2 µs, minimum phase separation of 500 ns, and 48-bit maximum count
  2. Digital I/O: 16 outputs (1 physical, 15 virtual) with a 5...30V DC output voltage range, 0.5 A on-state current, 2 mA minimum on-state current, and 0.5V DC maximum on-state voltage drop
  3. Signal Timing and Isolation: 2 ms time delay at signal exchange, 50V continuous basic insulation between inputs/outputs and backplane (type tested for 60s at 720V DC), and no I/O isolation
  4. Environmental and Immunity Ratings: Operating temperature -20...65 °C, nonoperating temperature -40...85 °C, 5...95% noncondensing humidity, 25 g nonoperating shock (35 g panel mount), 2 G vibration at 10...500 Hz, and ESD immunity of 6 kV contact and 8 kV air discharges
  5. Physical and Connection Specifications: Dimensions 31.5 mm width, 62 mm height, 20 mm depth, IP20 enclosure rating, screw connections with 0.22...0.25 Nm terminal torque, and 60 mA current draw at 3.3V DC
2080-MOT-HSC

Product Information

Technical Specifications

Specifications for 2080-MOT-HSC

ParameterValue
I/O IsolationNone
I/O Status IndicationLED
Time delay at signal exchange2 ms
Suitable for safety functionsYes
Digital inputs configurableYes
Digital outputs configurableYes
Type of voltage (input voltage)DC
Type of output voltageDC
Type of digital outputOther
Type of electric connectionScrew connection
Wiring category2 - on signal ports
Wire sizeSolid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum
Isolation voltageInput module: 50V (continuous), Basic Insulation Type, Inputs/Outputs to Backplane. Type tested for 60s @ 720V DC, Inputs/Outputs to Backplane
RedundancyNo
Short-circuit protection, outputs availableNo
Bus current draw60mA @ 3.3V DC
Width31.5 mm
Height62 mm
Depth20 mm
ShockIEC 60068-2-27 (Test Ea, unpackaged shock): 25 g, nonoperating, 35 g (Panel Mount) nonoperating
VibrationIEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
Terminal screw torque0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Surrounding air temperature, max65 °C
North American temperature codeT4
EmissionsCISPR 11 (IEC 61000-6-4): Class A
ESD immunityIEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
Relative humidityIEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing
ParameterValue
Conducted RF immunityIEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
EFT/B immunityIEC 61000-4-4: ±2kV @ 5kHz on signal ports
Operating temperature-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
Surge transient immunityIEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports
Nonoperating temperature-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
Radiated RF immunityIEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
On-state voltage drop, max0.5V DC
Reverse polarity protectionNone
Output on-state current0.5 A
Number of outputs16 (1 physical output, 15 virtual)
Enclosure type ratingMeets IP20
Output voltage range5...30V DC
Off-state voltage, max1.0V DC
On-state current, min2 mA
Number of inputs1 Quadrature (ABZ) differential input
Pulse width, min2 μs
Input impedance, nom3580 ?
Input frequency, max250 kHz (50% duty)
Maximum count48 bit
Phase separation, min500 ns
Input current range2 mA
Input voltage range0...30V DC
Off-state leakage current0.5 mA
ON-state voltage range2.6...30V DC
RepairableNOT_REPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height5.207
Lead Time5
Dimension Width6.502
Dimension Length10.389
Stock StatusSTOCKED
Weight52.163
Weight UnitG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Allen Bradley 2080-MOT-HSC High-Speed Counter Module for Micro800