- 140G-M0I3-D60-SD
The Rockwell 140G-M0I3-D60-SD is a three-pole motor protection circuit breaker with an 800 A frame and a rated permanent current of 600 A. It uses an electronic LSIG protection unit covering long-time, short-time, instantaneous, and ground fault protection. Instantaneous trip range is 900 to 7200 A; long-time setting is 0.4 to 1 x In (240 to 600 A). Rated impulse withstand voltage is 8 kV, insulation voltage is 1000 V per IEC, and rated ultimate short-circuit breaking capacity is 80 kA at 440 V AC, 50/60 Hz per IEC 60947-2. Connection is front-side screw type; degree of protection is IP40. Dimensions are 268 mm high, 210 mm wide, and 103.5 mm deep.
- 140G-M0I3-D63
The Rockwell 140G-M0I3-D63 is a 3-pole motor protection circuit breaker in the M-Frame with an 800 A rating and a 630 A trip unit. It uses an electronic LSIG trip unit for long-time, short-time, instantaneous, and ground-fault protection. The UL interrupting rating is 100 kA at 480 V. The breaker is UL Listed, CSA Certified, CE, and CCC. It is not repairable. Dimensions are 29.21 cm height, 30.48 cm width, and 36.322 cm length; weight is 10.084 kg. Stock status is non-stocked, with a lead time of 42.
- 140G-M0I4-D63
Rockwell motor protection circuit breaker, model 140G-M0I4-D63, is an 800 A M-Frame device with LSIG electronic trip adjustment. It provides an IEC breaking capacity of 120kA at 415V and a UL interrupting rating of 100kA at 480V. The breaker is UL Listed, CSA Certified, CE compliant, and CCC certified, and it complies with UL489, CSA22.2 No. 5, and IEC 60947-2. It is not repairable. Dimensions are 29.464 cm height, 37.084 cm width, and 30.48 cm length; weight is 12.995 kg. Stock status is non-stocked, with a lead time of 42.
- 140G-M0K3-D63
The Rockwell 140G-M0K3-D63 is a 3-pole molded case motor protection circuit breaker in the M-Frame with an 800 A rating and a 630 A trip unit. It uses LSIG-MM adjustment and provides electronic LSIG protection. Breaking capacity is 120 kA at 415 V per IEC. The breaker is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 28.5 cm high, 30.5 cm wide, and 37.0 cm long; weight is 9.48 kg. The unit is not repairable and is non-stocked, with a lead time of 36.
- 140G-M0K4-D63
Rockwell motor protection circuit breaker, model 140G-M0K4-D63, with electronic protection and a 630 A trip unit rating in an 800 A M-frame. It is not repairable. Dimensions are 28.5 mm high, 30.5 mm wide, and 37.0 mm long. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2.
- 140G-M0X3
The Rockwell 140G-M0X3 is a motor protection circuit breaker rated 800 A with a UL interrupting rating of 100kA at 480V. It is UL Listed, CSA Certified, CE, and CCC. Dimensions are 33.528 mm height, 31.75 mm width, and 37.211 mm length, with a weight of 8.106. The device is not repairable.
- 140G-M0X4
The Rockwell 140G-M0X4 is a 4-pole motor protection circuit breaker rated 800 A with thermal magnetic or electronic protection. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 30.8 cm height, 36.8 cm width, and 29.2 cm length; weight is 10.466 kg. The unit is not repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 42. No interrupting capacity, voltage rating, or application suitability is stated in the supplied data.
- 140G-M1B
The 140G-M1B is a motor protection circuit breaker from Rockwell. It offers a choice of operating mechanisms. Interrupting ratings range from 18 to 100 kA. The device is intended for global application.