Q1Can you supply the ROCKWELL 150-C251NCR?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C251NCR cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C251NCR
Material Number
—
Manufacturer
ROCKWELL
Product ID
107475

Get a Free Quote

Request pricing and availability for 150-C251NCR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
Fan power rating
40 VA
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
30.132
See all specifications

Product Highlights

  1. Start and Stop Modes: Supports soft start, current limit start, kick start, and soft stop, with selectable initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, current limit of 150%, 250%, 350%, or 450% of full load current, and start times of 2, 5, 10, 15, 20, 25, or 30 seconds
  2. Motor Protection: Integrated motor overload protection with selectable trip class 10, 15, or 20, internal bypass, and short-circuit protection device performance Type 1
  3. Power Ratings: Line-connected motor power up to 90...160 kW at 500 V AC, 50 Hz, 3-phase, with line current 84...251 A at 500/575 V AC, delta-connected motor power up to 315 kW at 500 V AC, 50 Hz, 3-phase, with delta current 145...435 A at 500/575 V AC
  4. Control and Auxiliary Contacts: Rated control supply voltage 24 V AC at 50/60 Hz or 24 V DC, control power during start with fan 200 mA at 120 V AC, 120 mA at 240 V AC, or 600 mA at 24 V AC/DC, and one normally open auxiliary contact (TB-97, -98) rated 0.6 A at 120 V AC and 0.3 A at 240 V AC
  5. Environmental and Compliance: Open-type enclosure with IP2X degree of protection, operating temperature -5 to 50 °C, pollution degree 2, altitude up to 2000 m, and EMC immunity surge transient per EN/IEC 60947-4-2
150-C251NCR

Product Information

Technical Specifications

Specifications for 150-C251NCR

ParameterValue
Product FamilySMC-3
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Fan power rating40 VA
Overload current84 A
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max90...160 kW @ 500V AC @ 50Hz, 3-phase
Delta connected motor power, max315 kW @ 500V AC @ 50Hz, 3-phase
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Line connected motor current84...251A @ 500/575V AC, 3-phase
Delta connected motor current145...435A @ 500/575V AC, 3-phase
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max18 kA @ maximum standard fuse 700 A for line device opsal current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
ParameterValue
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight30.132
ShockOpsal: 15 G
Width225 mm (8.86 in)
Depth265.3 mm (10.45 in)
Height560 mm (22.05 in)
Cable size0.2...2.5 mm2 (24...14 AWG) for control terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation147 W
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Mounting hole size11.5 mm
Number of polesEquipment is designed for 3-phase only for power circuit
Power pole holesTwo M10 x 1.5 diam holes per power pole for load power terminals
EnclosureOpen type
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height33.604
Lead Time22
Dimension Width30.81
Dimension Length63.805
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.