- 150-F60NBRD
The Rockwell Allen-Bradley 150-F60NBRD is an SMC Flex soft starter with a 60 A controller rating (10–40 Hp at 460 V AC) and an integrated display. Control voltage is 24 V AC/DC, with rated control supply voltage of 24 V at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz, and the rated operating voltage Ue is 200. Overload current ratings are 12 A for line-connected devices and 20.8 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Control options include brake control. The transformer control module is rated 75 VA at 100–240 V AC (-15%, +10%).
- 150-F60NCD
The ROCKWELL 150-F60NCD is a SMC Flex soft starter with an open-type enclosure, rated 60 A and 10-40 Hp at 460V AC. It operates from 200...600V AC (-15%, +10%) per UL/CSA/NEMA and 50/60 Hz for the power circuit, with control voltage of 100...240V AC. A display is included. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is provided. Line-connected motor current is 12...60A at 500/575V AC, three-phase; delta-connected motor current is 20.8...104A at 500/575V AC, three-phase. Dimensions are 150 mm width, 203 mm depth and 321 mm height, with 6.495 kg weight.
- 150-F60NCDB
The Rockwell 150-F60NCDB is a SMC Flex soft starter with an integrated display, configured for pump control. It is rated 60 A and 10–40 Hp at 460 V AC, with a maximum line-connected motor power of 50 Hp at 575 V AC, 60 Hz, three-phase. Control voltage is 100...240 V AC, and the rated operating voltage Ue is 200 V. The power circuit operates at 50/60 Hz and includes an RC snubber network for DV/DT protection, with a repetitive peak inverse voltage rating of 1600 V per UL/CSA/NEMA. Overload current is 12 A for line-connected devices and 20.8 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC.
- 150-F60NCDD
The ROCKWELL 150-F60NCDD is a SMC Flex smart motor controller configured as a soft starter with an integrated display and internal bypass. Its controller rating is 60 A, 10-40 Hp at 460 V AC. Control voltage is 100...240 V AC, and the rated operational voltage for the power circuit is 200...600 V AC (-15%, +10%) per UL/CSA/NEMA. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is included. Line connected motor current is 12...60 A at 500/575 V AC, 3-phase; delta connected motor current is 20.8...104 A at 500/575 V AC, 3-phase. The enclosure is open type, rated IP20 per IEC for the power circuit, with dimensions 150 mm width, 203 mm depth and 321 mm height.
- 150-F60NCR
The ROCKWELL 150-F60NCR is an SMC Flex smart motor controller configured as a soft starter with an open-type enclosure and a heatsink thyristor modular power pole construction. It is rated 60 A, with line-connected motor current of 12...60 A at 500/575 V AC, 3-phase, and delta-connected motor current of 20.8...104 A at 500/575 V AC, 3-phase. Rated operational voltage is 200...600 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, at 50/60 Hz. Control supply is 24 V AC/DC. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is included, and a display is fitted. Dimensions are 150 mm wide, 203 mm deep and 321 mm high.
- 150-F60NCRB
The Rockwell 150-F60NCRB is a soft starter rated 60 A and 10–40 Hp at 460 V AC, with an integrated display and internal bypass. It operates at 50/60 Hz with a rated operational voltage of 200–600 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, and 24 V AC/DC control supply. Line-connected motor current is 12–60 A at 500/575 V AC, 3-phase; delta-connected motor current is 20.8–104 A at 500/575 V AC, 3-phase. Control options include pump control, with trip classes 10, 15, 20, and 30. Integrated motor overload protection is included. The open-type enclosure measures 150 mm wide, 203 mm deep, and 321 mm high, and operates from -5 to 50 °C.
- 150-F60NCRD
The Rockwell 150-F60NCRD is an SMC Flex soft starter with an integrated display and internal bypass, rated 60 A and 10-40 Hp at 460V AC. Control voltage is 24V AC/DC. The power circuit operates at 50/60 Hz with a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA and a rated insulation voltage of 500V per IEC. Line-connected motor current is 12...60 A at 500/575V AC, three-phase. Overload current is 12 A line-connected and 20.8 A delta-connected. Trip classes are 10, 15, 20 and 30. Brake control is a control option. The controller measures 150 mm wide, 203 mm deep and 321 mm high, and weighs 6.87 kg.
- 150-F625NBA
The Rockwell 150-F625NBA is an SMC Flex soft starter rated 625 A, 500 Hp at 460V AC. It operates on 200-460V AC, 3-phase, 50/60 Hz power circuits with a 230...240V AC control voltage. The controller includes an LCD display and electronic motor overload protection. Overload current ratings are 208 A for line-connected devices and 283 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Maximum line-connected motor power is 800 Hp at 600V AC, 60 Hz, 3-phase; maximum delta-connected motor power is 900 Hp at 575V AC, 60 Hz, 3-phase. Power circuit protection includes an RC snubber network and a 1400V repetitive peak inverse voltage rating per UL/CSA/NEMA.