- 140G-H6C4-C35
Product identification: ROCKWELL 140G-H6C4-C35. The Allen Bradley 140G-H6C4-C35 is a thermal magnetic motor protection circuit breaker in the H-frame size, rated 125 A. It is not repairable. Dimensions are 13.716 mm high, 14.732 mm wide, and 21.844 mm long, with a weight of 2.073 kg.
- 140G-H6C4-C70
The Rockwell 140G-H6C4-C70 is a four-pole motor protection circuit breaker with a rated permanent current of 70 A and a 125 A frame size. It uses a fixed thermal/fixed magnetic trip unit, with thermal trip current (Ir) of 70 A and magnetic trip current (Im) of 700 A. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated impulse withstand voltage (Uimp) is 8 kV; insulation voltage (Ui) is rated 1000 V per IEC. IEC 60947-2 ratings include Icu 70 kA at 500 V DC with three poles in series, thermal-magnetic trip unit only, and Ics 100% Icu under the same conditions. Connection is front-side screw type; degree of protection is IP40. Dimensions are 130 mm height, 120 mm width, and 82.5 mm depth.
- 140G-H6F3-D10
The Rockwell 140G-H6F3-D10 is a 3-pole motor protection circuit breaker with a rated current of 100 A. It provides a breaking capacity of 70 kA at 415 V AC. The device is not repairable. Dimensions are 13.46 cm in height, 14.99 cm in width, and 22.23 cm in length, with a weight of 1.683 kg. The product is currently stocked. No additional technical specifications or certifications are provided.
- 140G-H6F3-D12
Rockwell motor protection circuit breaker, model 140G-H6F3-D12. Rated current 125 A, 3 pole. Breaking capacity 70 kA at 415 V. The unit is not repairable. Dimensions are 13.49 cm height, 15.49 cm width, and 21.69 cm length; weight is 1.692 kg. It is marked as preferred availability and stocked, with a lead time of 5. No manufacturer part number or order code is supplied. The legacy description's 600 VAC rating and adjustable thermal/magnetic trip are not confirmed by the structured parameters and are omitted.
- 140G-H6F3-D16
The Rockwell 140G-H6F3-D16 is a 160 A H-frame motor protection circuit breaker. It is rated 65 kA at 480 V and complies with IEC 60947-2. The unit is not repairable. Dimensions are 15.113 in height, 13.462 in width, and 22.098 in length, with a weight of 1.674 lb.
- 140G-H6F4-D16
The Rockwell 140G-H6F4-D16 is a motor protection circuit breaker in the H-frame size with a 160 A rating. It complies with IEC 60947-2 and has a UL interrupting rating of 65 kA at 480 V. The device is not repairable. Dimensions are 15.0 mm height, 21.5 mm width, and 13.0 mm length, with a weight of 2.111 kg.
- 140G-H6H4-C25
The Rockwell 140G-H6H4-C25 is a 4-pole motor protection circuit breaker with a 25 A trip unit rating and electronic protection. It is UL Listed, CSA Certified, CE marked, and CCC certified, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. IEC breaking capacity is 70 kA at 415V. Dimensions are 13.589 cm height, 15.24 cm width, and 22.352 cm length; weight is 2.17 kg. The unit is not repairable. It is non-stocked with a lead time of 66. Preferred availability and quick turnaround are both false.
- 140G-H6H4-D16
The Rockwell 140G-H6H4-D16 is a motor protection circuit breaker with a 160 A electronic trip unit and LSI adjustment. Its IEC breaking capacity is 70 kA at 415 V. The unit is not repairable. Dimensions are 13.0 mm height, 14.501 mm width, and 21.501 mm length.