- 140G-M5F4-D63
The Rockwell 140G-M5F4-D63 is a 4-pole molded case circuit breaker in the M-frame size, rated 800 A. It provides an IEC breaking capacity of 50 kA at 415 V and a UL interrupting rating of 50 kA at 480 V. The breaker complies with UL489, CSA22.2 No. 5, and IEC 60947-2, and holds UL Listed, CSA Certified, CE, and CCC certifications. It is not repairable and is classified as non-stocked with a lead time of 42 days. Dimensions are 30.5 cm high, 30.0 cm wide, and 37.501 cm long, with a weight of 11.794 kg.
- 140G-M5H3-D80-CJ
Rockwell 140G-M5H3-D80-CJ motor protection circuit breaker, 3-pole, rated permanent current Iu 800 A, toggle control, screw front-side main circuit connection, built-in fixed device. Electronic LSI protection: L I1 = 0.4...1 x In (320...800 A), t1 = 3, 6, 9, 18 s; S I2 = 0.6...10 x In (480...8000 A), t2 = 0.05, 0.1, 0.25, 0.5 s; I I3 = 1200...8400 A. Interrupting rating 50 kA at 480 V AC, 50/60 Hz per NEMA, UL, CSA; Icu per IEC 60947-2 85 kA at 220...230 V AC, 50/60 Hz. Rated impulse withstand voltage 8 kV, insulation voltage 1000 V per IEC, IP40, 210 mm wide, 268 mm high, 103.5 mm deep.
- 140G-M5H3-D80-Z1
Product identification: ROCKWELL 140G-M5H3-D80-Z1. The Allen-Bradley 140G-M5H3-D80-Z1 is a three-pole motor protection circuit breaker rated at 800 A. It uses an M frame and is not repairable. Dimensions are 29.464 mm high, 31.496 mm wide, and 38.354 mm long, with a weight of 10.787 kg. The device is non-stocked.
- 140G-M5H4-D63
The Rockwell 140G-M5H4-D63 is a motor protection circuit breaker in the M-Frame with an 800 A rating and an electronic trip unit rated 630 A. Its IEC breaking capacity is 50 kA at 415 V. The device is UL Listed, CSA Certified, CE marked, and CCC certified, and it complies with UL489, CSA22.2 No. 5, and IEC 60947-2. It is not repairable and is non-stocked, with a lead time of 36. Dimensions are 28.999 cm high, 30.0 cm wide, and 37.0 cm long; weight is 13.044 kg.
- 140G-M5H4-D80-AB
The Rockwell 140G-M5H4-D80-AB is a 4-pole molded case circuit breaker with a rated permanent current Iu of 800 A and a toggle control element. It uses electronic LSI protection: L trip I1 = 0.4...1 x In (320...800 A), t1 = 3, 6, 9, 18 s; S trip I2 = 0.6...10 x In (480...8000 A), t2 = 0.05, 0.1, 0.25, 0.5 s; and I trip I3 = 1200...8400 A. Interrupting rating is 50 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated impulse withstand voltage is 8 kV, insulation voltage is 1000 V per IEC, and rated ultimate short-circuit breaking capacity is 85 kA at 220...230 V AC, 50/60 Hz per IEC 60947-2. Main circuit connection is front-side screw. Dimensions are 280 mm wide, 268 mm high, and 103.5 mm deep, with IP40 protection.
- 140G-M5I3-D63
Rockwell motor protection circuit breaker, display model 140G-M5I3-D63, M-Frame, 800 A rating, 3-pole, electronic protection with a 630 A trip unit rating. Certifications: UL Listed, CSA Certified, CE, CCC. Standards compliance: UL489, CSA22.2 No. 5, IEC 60947-2. Dimensions are 30.734 cm height, 31.242 cm width, and 38.862 cm length; weight is 10.315 kg. The unit is not repairable. Stock status is non-stocked, preferred availability is false, and quick turnaround is false. Lead time is 42. No interrupting capacity, voltage rating, LSIG functions, or ground fault capability is stated in the supplied structured parameters.
- 140G-M5I4-D63
Product identification: ROCKWELL 140G-M5I4-D63. The Allen-Bradley 140G-M5I4-D63 is an 800 A M-frame motor protection circuit breaker with LSIG electronic adjustment. It provides 50 kA breaking capacity at 415 V per IEC and 50 kA interrupting rating at 480 V per UL. The unit is UL Listed, CSA Certified, CE, and CCC marked. Dimensions are 22.86 mm height, 22.86 mm width, and 29.21 mm length. It is not repairable.
- 140G-M5K3-D60-SD-AA
The Rockwell 140G-M5K3-D60-SD-AA is a three-pole motor protection circuit breaker with a rated permanent current Iu of 600 A and an 800 A frame size. It uses a toggle control element and includes one auxiliary change-over contact. Integrated earth fault protection is provided; no integrated under-voltage release is included. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 1000 V per IEC. Maximum reverse-fed voltage is 690 V AC per IEC. Electronic protection settings include long-time I1 = 0.4 to 1 x In (240 to 600 A), short-time I2 = 0.6 to 10 x In (360 to 6000 A), and instantaneous I3 = 900 to 7200 A. Electrical life is 7000 cycles at 600 to 630 A or 5000 cycles at 800 A, at 415 V AC.