- 140G-G6C4-C25
The ROCKWELL 140G-G6C4-C25 is a motor protection circuit breaker rated 125 A. It provides an IEC breaking capacity of 70 kA at 415 V and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. The unit is not repairable. Dimensions are 12.827 height, 14.351 width, and 13.462 length, with a weight of 1.499.
- 140G-G6C4-C32
The Rockwell 140G-G6C4-C32 is a motor protection circuit breaker rated 125 A with fixed thermal and fixed magnetic adjustment. It is compliant with UL489, CSA22.2 No. 5, and IEC 60947-2. The device is not repairable. Dimensions are 12.827 in height, 13.462 in width, and 14.351 in length, with a weight of 1.497 lb.
- 140G-G6C4-C40
The Rockwell 140G-G6C4-C40 is a G-Frame motor protection circuit breaker rated 125 A with a 40 A trip unit. It is not repairable. Dimensions are 4.445 in height, 11.557 in width, and 11.049 in length; weight is 0.102 kg.
- 140G-G6C4-C45
The Rockwell 140G-G6C4-C45 is a fixed thermal magnetic molded case circuit breaker in a G frame size. It has a 125 A frame rating and a 45 A trip unit rating. The breaker is not repairable. Dimensions are 18.923 cm height, 21.59 cm width, and 16.002 cm length, with a weight of 1.746 kg. It is non-stocked, not preferred for availability, and not available for quick turnaround; lead time is 42. The legacy description's 70 kA short-circuit breaking capacity, 40°C rating, and standards certifications are not confirmed by the structured parameters and are omitted.
- 140G-G6C4-C63
The Rockwell 140G-G6C4-C63 is a motor protection circuit breaker with fixed thermal and fixed magnetic adjustment. It has a rated current of 125 A and an IEC breaking capacity of 70 kA at 415 V. Dimensions are 13.487 height, 13.106 width, and 14.707 length, with a weight of 1.483. It is not repairable.
- 140G-G6C4-C70
The ROCKWELL 140G-G6C4-C70 is a motor protection circuit breaker with a G-frame and a fixed thermal, fixed magnetic trip unit. It carries a 125 A current rating and an IEC breaking capacity of 70 kA at 415 V. It conforms to UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 13.208 mm height, 13.208 mm width, and 14.224 mm length, with a weight of 1.52 kg.
- 140G-G6C4-C90
The Rockwell 140G-G6C4-C90 is a motor protection circuit breaker with a 125 A current rating and a 90 A trip unit rating. It carries UL Listed, CSA Certified, CE, and CCC certifications. Dimensions are 12.499 height, 13.8 width, and 14.0 length, with a weight of 1.514. The unit is not repairable.
- 140G-G6C4-D10
The Rockwell 140G-G6C4-D10 is a motor protection circuit breaker in the G frame with a 125 A rating and a 100 A trip unit rating. It is a four-pole device with a fixed thermal and fixed magnetic trip unit. The interrupting capacity is 65 kA at 480 V. The breaker is not repairable. Dimensions are 12.802 cm high, 15.392 cm wide, and 14.097 cm long, with a weight of 1.154 kg. It is non-stocked, not preferred for availability, and not available for quick turnaround; lead time is 42. This device is intended for electrical protection in industrial circuits within the stated ratings.