Q1Can you supply the ROCKWELL 1756-CFM?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 1756-CFM cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
1756-CFM
Material Number
—
Manufacturer
ROCKWELL
Product ID
106719

Get a Free Quote

Request pricing and availability for 1756-CFM.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type of supply voltage
DC
Isolation voltage
250V (continuous), reinforced insulation type, I/O-to-backplane, 250V (continuous), basic insulation type, I/O group-to-group
Short-circuit protection, outputs available
No
Frequency
Resolution: 0.0005 Hz
Output current per point
1 @ 10...31.2V DC @ 20mA @ 4.5...5.5V DC
Weight
0.354
See all specifications

Product Highlights

  1. Flowmeter Inputs: Two flowmeter (F) inputs support all modes with a maximum input frequency of 100 kHz and selectable input thresholds of 50 mV, 1.3 V, and 4 V
  2. Gate Inputs and Totalizer Mode: Two gate inputs are used in Totalizer mode for prover and store count, with a gate input voltage range of 4.5 to 5.5 V DC or 10 to 26.4 V DC and a maximum count range of 2,147,483,647
  3. Outputs: Two current-sourcing outputs rated IEC 1 A at 24 V DC, with a customer-supplied voltage source, output voltage ranges of 4.5 to 5.5 V DC at 3 to 20 mA per point or 10 to 31.2 V DC at 40 mA to 1 A per point, and electronic overload protection below 4 A
  4. Configurable Inputs and Filtering: Digital inputs are configurable, with firmware-selectable high-speed 100 kHz or low-pass filtering below 70 Hz on F0 and F1 inputs and software-selectable mechanical filter debouncing on Z0 and Z1 inputs
  5. Power and Isolation: 1.7 W total backplane power, 300 mA at 5.1 V and 16 mA at 24 V current draw, and 250 V continuous reinforced insulation between I/O and backplane
  6. Environmental and Compliance: Operating temperature 0 to 60 C, nonoperating temperature -40 C, 5 to 95% noncondensing relative humidity, 30 G operating shock, 2 G vibration at 10 to 500 Hz, and IEC 61000-6-4 emissions
1756-CFM

Product Information

Technical Specifications

Specifications for 1756-CFM

ParameterValue
Suitable for safety functionsNo
Digital inputs configurableYes
Digital outputs configurableNo
Voltage type of supply voltageDC
Type of electric connectionScrew connection
Total backplane power1.7 W
Thermal dissipation20.4 btu/h
Current draw300mA @ 5.1V, 16mA @ 24V
Module keyingElectronic, software configurable
Outputs2 current sourcing
Power dissipation, max6 W @ 60 °C (140 °F)
InputsTwo flowm (F) inputs used for all modes, Two gate inputs used in Totalizer mode for prover/store count, 4 (2 per channel)
Isolation voltage250V (continuous), reinforced insulation type, I/O-to-backplane, 250V (continuous), basic insulation type, I/O group-to-group
Wire category2 on signal ports, 1 on power ports
RedundancyNo
Short-circuit protection, outputs availableNo
High resolution, max100 khz
FrequencyResolution: 0.0005 Hz
Slot width1
RTB keyingUser-defined mechanical
ShockOperating: 30 G, Non operating: 50 G
Vibration2 G @ 10...500 Hz
Surrounding air temperature, max60 °C
North American temperature codeT4
EmissionsIEC 61000-6-4
ESD immunity6 kV contact discharges, 8 kV air discharges
Relative humidity5...95% noncondensing
Conducted RF immunity10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
EFT/B immunity±4kV @ 5kHz on unshielded output and power ports, ±4kV @ 5kHz on shielded input ports
Operating temperature0 to 60 °C
Surge transient immunity±1 kV line-line (DM) and ±2 kV line-earth (CM) on unshielded output and power ports, ±2 kV line-earth (CM) on shielded input ports
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature-40 °C
On-state voltage drop, max0.6 ? x current
ParameterValue
Off-state leakage current, max<300 μA @ 31.2V DC
Reverse polarity protectionOutputs only
Output switching time<50 μs turn on, <300 μs turn off, Outputs triggered by Total, all other “turn-on” and “turn-off” times <1 ms
Output controlAny number of outputs is assignable to any of two flowm channels each output can have 2 “turn-on” and “turn-off” preset values
Output typeIEC 1 A 24V DC
Output voltage sourceCustomer supplied
Overload currentElectronic (<4 A)
Surge current2 A @ 50 ms, repeatable every 2s
Output current per point1 @ 10...31.2V DC @ 20mA @ 4.5...5.5V DC
Output reverse polarity protectionYes (if wired incorrectly, module outputs can be permanently disabled.)
Output short circuit protectionElectronic (no indication of fault. remove overload and toggle output on/off to restore.)
Output voltage range, nom5V ops: 4.5...5.5V DC @ 3...20mA load per point, 12/24V ops: 10...31.2V DC @ 40mA...1 A load per point
Input frequency, max100 kHz @ flowm inputs (overrange occurs at 100 kHz)
Gate input on-state current, min4 mA
Gate input on-state current, nom15 mA
Input sampling periodUser selectable
Count range, max2, 147, 483, 647
Flowmeter input impedance5 k? ±30% resistive
Mechanical filter debouncing (Z0 & Z1 Inputs)Software selectable
Gate input voltage range5V ops: 4.5...5.5V DC @ 12/24V ops: 10...26.4V DC
Filtering (inputs F0 & F1)Firmware selectable: high-speed 100 kHz or low-pass filter for frequencies <70 Hz
Flowmeter input voltage±30V, selectable input thresholds of 50mV @ 1.3V and 4V: ±30V peak unterminated open circuit voltage, magnetic pickup, TTL compatible, input voltage >1.3V DC is Logic 1 and -0.7...1.3V DC is Logic 0, 12...24V DC powered preA output, 4V DC threshold
Totalizer fill and proverYes
Enclosure typeNone (open-style)
RepairableREPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height5.715
Lead Time5
Dimension Width18.415
Dimension Length23.495
Stock StatusSTOCKED
Weight0.354
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?