Product Model
1756-OX8I
Material Number
—
Manufacturer
ROCKWELL
Product ID
106213

Get a Free Quote

Request pricing and availability for 1756-OX8I.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type of supply voltage
DC
Type of voltage (input voltage)
DC
Short-circuit protection, outputs available
No
Switching frequency, max
1 ops/3 s (0.3 Hz at rated load)
Operating temperature
0 to 60 °C
Weight
0.363
See all specifications

Product Highlights

  1. Output Configuration: 8 individually isolated relay outputs arranged as 8 normally open and 8 normally closed contacts, two points per group
  2. Contact Ratings: 1 A at 5 to 30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC, 1.5 A at 120 V AC, and 0.75 A at 240 V AC, with a minimum load current of 10 mA per point
  3. Isolation: 250 V continuous basic insulation between outputs and backplane and between outputs
  4. Switching Characteristics: Maximum switching frequency of 0.3 Hz at rated load, 13 ms maximum OFF to ON and ON to OFF delay, 1.2 microseconds mean bounce time, and expected contact life of 300 kHz resistive or 100 kHz inductive
  5. Protection and Fault Behavior: Outputs are not short-circuit protected and not fused, a fused interface module is recommended, and each point can hold last state or be set On or Off in fault and program modes
1756-OX8I

Product Information

Technical Specifications

Specifications for 1756-OX8I

ParameterValue
Isolation250 V continuous between outputs
Number Of Channels8
Suitable for safety functionsNo
Digital inputs configurableNo
Digital outputs configurableNo
Voltage type of supply voltageDC
Type of voltage (input voltage)DC
Type of digital outputRelay
Type of electric connectionScrew connection
Bounce time, mean1.2 μs
Total backplane power2.9 W
Thermal dissipation10.57 btu/h
Current draw100mA @ 5.1V, 100mA @ 24V
Expected contact life300 kHz, resistive, 100 kHz, inductive
Module keyingElectronic, software configurable
Outputs8 N.O., 8 N.C. individually isolated (two points per group)
Scheduled outputsSynchronization within 16.7 s max, reference to the coordinated system time
Power dissipation, max3.1 W @ 60 °C (140 °F)
Contact current rating1A @ 5...30V DC, 0.5A @ 48V DC, 0.22A @ 125V DC, 1.5A @ 120V AC, 50/60 Hz, 0.75A @ 240V AC, 50/60 Hz
Isolation voltage250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Wire categoryWire category: 1
FusingNot protected. A fused IFM is recommended to help protect outputs
RedundancyNo
Short-circuit protection, outputs availableNo
Pilot dutyC300, R150
Initial contact resistance, max100 m? @ 6V @ 1A
Switching frequency, max1 ops/3 s (0.3 Hz at rated load)
States in fault mode per pointHold last state, On or Off (Off is default)
ParameterValue
States in program mode per pointHold last state, On or Off (Off is default)
Slot width1
RTB keyingUser-defined mechanical
ShockOperating: 30 G, Non operating: 50 G
Vibration2 G @ 10...500 Hz
Surrounding air temperature, max60 °C
North American temperature codeT4A
EmissionsIEC 61000-6-4
ESD immunity6 kV contact discharges, 8 kV air discharges
Relative humidity5...95% noncondensing
Conducted RF immunity10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
EFT/B immunity±4kV @ 5kHz on signal ports
Operating temperature0 to 60 °C
Surge transient immunity±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature-40 °C
Oscillatory surge withstandIEEE C37.90.1: 3kV
Off-state leakage current per point, max0 mA
Load current per point, min10 mA
Output delay timeOFF to ON: 13 ms maximum, ON to OFF: 13 ms maximum
Operating voltage5...125V DC @ 10...240V AC
Enclosure typeNone (open-style)
RepairableREPAIRABLE
Preferred Availabilitytrue
Quick Turnaroundfalse
Dimension Height5.41
Lead Time5
Dimension Width18.009
Dimension Length22.2
Stock StatusSTOCKED
Weight0.363
Weight UnitKG
Dimension UnitCM