Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-SD3NBD SMC-50 Solid State Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-SD3NBD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-SD3NBD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-SD3NBD
Material Number
—
Manufacturer
ROCKWELL
Product ID
105502

Get a Free Quote

Request pricing and availability for 150-SD3NBD.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
100...240V AC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network
Operating frequency
47...63 Hz or DC for control power
Output current, max
300mA @ 24V DC supply (terminals 8 and 12) for control power
Weight
75.387
See all specifications

Product Highlights

  1. Controller Rating: 520 A SMC-50 controller with D3 rating, 3 poles, and single-direction function
  2. Motor Current and Power: Line-connected normal duty 174...520 A at 400/415/460 V AC 3-phase and 75...200 Hp at 230 V AC 60 Hz 3-phase, delta-connected normal duty 302...900 A at 400/415/460 V AC 3-phase and 250...700 Hp at 460 V AC 60 Hz 3-phase
  3. Control Voltage and Power: 100...240 V AC control voltage, 47...63 Hz or DC control power, 300 VA base power draw from control module with heat sink fan, 22 ms control power ride through, and CR 2032 control module battery
  4. Protection and Overload: Integrated electronic I2t motor overload protection, trip classes 5...30, trip current rating 118% of motor FLC, Type 1 SCPD, RC snubber network DV/DT protection, and metal oxide varistor transient protection rated 220 J
  5. Power Circuit Ratings: 1400 V repetitive peak inverse voltage per UL/CSA/NEMA, 6000 V rated impulse voltage per IEC, 2500 V dielectric withstand per IEC, and 500 V rated insulation voltage per IEC
  6. Fault Current Ratings: 42 kA at 600 V maximum standard available fault current with 2500 A non-time delay fuse typical for inside-delta connected motors, and 65 kA at 600 V maximum high-capacity available fault current with 1200 A time delay Class J or Class L fuse typical for inside-delta connected motors
  7. Configuration Options: Config tool not provided, must be ordered as option 150-SM6 or Human Interface Module (HIM) or configuration software such as Drive Exec, with optional parameter configuration and programming tools
  8. Operating Conditions: 40 to 65 C operating ambient temperature, -20 C rated surrounding temperature without derating, 5...95% noncondensing humidity, 2000 m altitude without derating, pollution degree 2, vertical mounting, and 15 cm minimum vertical clearance
  9. Physical and Environmental: Open type enclosure, IP00 overall with IP20 control terminals, 914.4 mm width, 355.6 mm depth, 1295.4 mm height, 75.387 kg weight, and ANSI/ISA-71.04-2013 class G3 atmospheric protection
150-SD3NBD

Product Information

Technical Specifications

Specifications for 150-SD3NBD

ParameterValue
Control Voltage100...240V AC
Controller RatingsD3
NOTEConfig tool not provided,must be ord as Option(150-SM6)or Human Interf Mod(HIM)or Config Software such as Drive Exec
With displayNo
Voltage type for actuatingAC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Controller rating520 A
Continuous duty power structure heat dissipation1560 W
Overload current for line connected devices174 A
Overload current for delta connected devices302 A
Controller typeSMC-50
Trip classes5...30
Trip current rating118% of motor FLC
Base power draw from control module with heat sink fan300VA @ 100...240V AC
DV/DT protectionRC snubber network
Repetitive peak inverse voltage rating1400V per UL/CSA/NEMA for power circuit
Operating frequency47...63 Hz or DC for control power
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor currentNormal/standard duty: 174...520A @ 400/415/460V AC, 3-phase
Delta connected motor currentNormal/standard duty: 302...900A @ 400/415/460V AC, 3-phase
Transient protectionMetal oxide varistors: 220 J
Insulation voltageRated 500V per IEC for power circuit
Line connected motor powerNormal/standard duty: 75...200Hp @ 230V AC, 60 Hz, 3-phase
Delta connected motor powerNormal/standard duty: 250...700Hp @ 460V AC, 60 Hz, 3-phase
High capacity available fault current, max65kA @ 600V, typical current 1200 A time delay Class J or Class L fuse for inside delta connected motors
Utilization categoryMG 1 per UL/CSA/NEMA for normal duty
Option power adder5VA @ 100...240V AC, 150-SM6 (for each option installed, add to base power to obtain total power requirement)
Standard controller featureTorque control
Standard available fault current, max42kA @ 600V, typical current 2500 A non-time delay fuse for inside delta connected motors
Optional controller featureParam configuration/progming tools
Integrated motor overload protectionYes
ParameterValue
Short circuit protection device performance (SCPD) typeType 1
Control power ride through22 ms for control power
Control module battery typeCR 2032 for control power
Overload typeElectronic - using I2t algorithm
Output current, max300mA @ 24V DC supply (terminals 8 and 12) for control power
Degree of protection (IP)IP00
ShockOpsal: 15 G
Width914.4 mm
Depth355.6 mm
Height1295.4 mm
Power terminal lugsTwo 13.5 mm (0.53 in) diam holes per power pole
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-20 °C
Humidity5...95% (noncondensing)
Protection against electrical shockIP00 (IP20 - control terminals only) per IEC
EMC emission levelsRadiated emissions: Class A (per EN 60947-4-2)
EMC immunity levelsSurge transient per EN 60947-4-2
Altitude2000 m (6560 ft) without derating, for ops above 2000...7000 m (6560...22965 ft) maximum, refer to Thermal Wizard
Pollution degree2
Mounting orientationVertical
Atmospheric protectionANSI/ISA - 71.04-2013, class G3 environment
Operating ambient temperature40 to 65 °C (104 to 149 °F) (refer to thermal wizard)
Number of poles3
Horizontal clearance, min0 cm
Vertical clearance, min15 cm
EnclosureOpen type
Metal partsPlated brass, copper or steel
Control modulesThermoset and thermoplastic moldings
Power polesHeatsink hockey puck thyristor modular design
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height33.02
Lead Time20
Dimension Width41.91
Dimension Length40.64
Stock StatusNON_STOCKED
Weight75.387
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp