- BC6-21-10-P-01
The ABB BC6-21-10-P-01 is a 3-pole mini contactor with two normally open main contacts and one normally closed main contact, plus one normally open auxiliary contact. Its 24 V DC control coil operates within 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power is 4 kW at 400 V and 500 V three-phase, and 2.2 kW at 230 V three-phase. Rated insulation voltage is 690 V, with a 6 kV impulse withstand rating. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight is 0.17 kg. Mechanical durability is 10,000,000 cycles. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and operates from -25 to +55 °C.
- BC6-21-10-P-05
The ABB BC6-21-10-P-05 is a 3-pole mini contactor with one normally closed and two normally open main contacts, plus one normally open auxiliary contact. It measures 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, and weighs 0.17 kg. Rated operational power is 2.2 kW at 230 V three-phase and 4 kW at 400 V or 500 V three-phase in AC-3. The control circuit is rated 220 to 240 V DC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C per IEC 60947-4-1. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting is supported on TH35-15 and TH35-7.5 rails per IEC 60715.
- BC6-21-10-P-16
The ABB BC6-21-10-P-16 is a 3-pole mini contactor with soldering pins, measuring 47.5 mm wide, 45.2 mm high, and 47.7 mm deep, with a net weight of 0.17 kg. It has two normally open main contacts and one normally closed main contact, plus one normally open auxiliary contact. Rated operational power is 4 kW at 400 V three-phase in AC-3, and rated operational current AC-1 is 12 A at 220/240 V and 380/440 V at both 40 °C and 55 °C. Coil control voltage is 8 V DC. Mechanical durability is 10,000,000 cycles. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC6-22-00-01
ABB BC6-22-00-01 mini contactor, 4-pole, with 2 NO and 2 NC main contacts and no auxiliary contacts. Control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Main circuit rated operational voltage is 690 V AC or 220 V DC, with rated insulation voltage 690 V and rated impulse withstand voltage 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for 40 °C and 55 °C. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- BC6-22-00-03
ABB BC6-22-00-03 mini contactor, 4-pole, with 2 NO and 2 NC main contacts and no auxiliary contacts. Coil voltage is 60 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC and 220 V DC, with rated insulation voltage 690 V and rated impulse withstand voltage 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V, three phase. Dimensions are 52.5 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.175 kg. Mechanical durability is 10,000,000 cycles.
- BC6-22-00-04
The ABB BC6-22-00-04 is a 4-pole mini contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. The DC control circuit is rated 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Main circuit ratings include 690 V AC and 220 V DC, a rated impulse withstand voltage of 6 kV, and a conventional free-air thermal current of 20 A. AC-1 rated operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 52.5 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.175 kg. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- BC6-22-00-05
The ABB BC6-22-00-05 is a 4-pole mini contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. The control circuit is rated 220 to 240 V DC, with coil operating limits of 0.85 to 1.1 x Uc at temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220 to 440 V. Screw terminals accept rigid conductors from 1 to 4 mm², with 9 mm stripping length and 0.8 to 1.1 N·m tightening torque.
- BC6-22-00-16
The ABB BC6-22-00-16 is a mini contactor with four poles: two main contacts NO and two main contacts NC. It has a 48 V DC control circuit coil, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C for 690 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.